Power Sources

DO NOT CONNECT THE  EQUIPMENT TO A POWER
SOURCE UNTIL READY TO "POWER UP''.  Make all
connections to the 2083/06 code input and relay connections
and set the DIP switches prior to power up.

The 2083/06 Code Translator does not contain an On/Off
Switch. The socket outlet shall be located near the equipment
and shall be readily accessible. The 120 V units are supplied
with a pendant 3-wire cord and plug for mating to the primary
source outlet. The 230 V units are supplied with a Euro style
IEC 320 type inlet. A suitable detachable cord should be
connected between the IEC 320 inlet and the power source.
The cord should conform to all national and local use code
requirements. A green POWER LED indicator located on the
rear panel illuminates when power is applied.

Code Translators are available in two models, depending on
the power source to be used:

AD2083/06

120VAC, 50/60 Hz

ADS2083/06X

230VAC, 50/60 Hz

The 2083/06 unit has fuse power protection. The fuse sizes for
replacement are;

120 V - 250 V, SB, 125 mA, 5 x 20 mm
230 V - 250 V, T,   125 mA, 5 x 20 mm

Operating Indicators

When the unit is receiving valid code, the green CODE LED,
on the rear panel, is illuminated.  The LED stays lit for 5
seconds after code is removed.  If this LED does not light, a
problem in the unit or its interconnection may be indicated.

If an alarm input is activated, the green ALARM LED
illuminates, and the alarm relay closes.  The ALARM LED
will go out and the alarm relay will open ten seconds after the
alarm input is reset or removed.

Controlling Pelco Receiver Features

The 2083/06 supports the transmitted codes for Pelco Intercept
Domes features.  This includes the standard American
Dynamics keyboard functions for camera Pan, Tilt, and Lens
control.  For those Pelco domes which implement preset
capability, the 2082/06 supports AD keyboard commands for
32 presets per receiver.

Pelco domes support the use of eight auxiliary actions.  The
first three Pelco dome auxiliary channels are controlled via the
normal AD keyboard AUX commands.  Pelco dome auxiliary
channels 4 through 8 are controlled from the AD keyboard
using the commands indicated in Table 4, page 5.

In addition, the 2083/06 provides AD keyboard commands for
the control of several unique Pelco Intercept Domes functions.
These additional functions and the associated AD keyboard
commands are shown in Table 4, page 5.

6

OPERATION

IF YOU ENCOUNTER ANY PROBLEMS

OPERATING THIS UNIT, OR NEED ASSISTANCE,

CALL OUR TECHNICAL SUPPORT CENTER:

within the United States:  1-800-442-2225

outside the United States:  (914) 624-7640

Summary of Contents for 2083/06

Page 1: ...es for the model 2083 06 Code Translator The 2083 06 Code Translator is an interface unit used with American Dynamics Switching Systems This unit translates codes to enable the use of all American Dyn...

Page 2: ...rchaser under a license for use on a single system NOTE Information furnished by SENSORMATIC is believed to be accurate and reliable However no responsibility is assumed by SENSORMATIC for its use nor...

Page 3: ...ed with the packing list with your order Be sure to save 1 The shipping cartons and insert pieces They are the safest material in which to make future shipments of the product 2 The IMPORTANT SAFEGUAR...

Page 4: ......

Page 5: ...era Block Assignment 2 Camera Mode 2 Baud Rate Selection 2 Connections 5 Pelco Interface Connectors 5 Control Code Connector 5 Data Line Connector 5 Operation 6 Power Sources 6 Operating Indicators 6...

Page 6: ......

Page 7: ...slator may be surface or rack mounted in any convenient location with adequate ventilation Rack Mounting The 2083 06 is shipped with the mounting ears installed flush with the front panel and can be m...

Page 8: ...ble 3 pages 3 and 4 for the camera number range settings of switches S1 S2 S3 S4 and S6 Camera Mode The S5 DIP switch is used to define the maximum range of camera numbers that can be processed via ea...

Page 9: ...7 128 0 0 0 0 1 1 129 160 0 0 0 1 0 0 161 192 0 0 0 1 0 1 193 224 0 0 0 1 1 0 225 256 0 0 0 1 1 1 257 288 0 0 1 0 0 0 289 320 0 0 1 0 0 1 321 352 0 0 1 0 1 0 353 384 0 0 1 0 1 1 385 416 0 0 1 1 0 0 41...

Page 10: ...0 0 0 0 529 544 1 0 0 0 0 1 545 560 1 0 0 0 1 0 561 576 1 0 0 0 1 1 577 592 1 0 0 1 0 0 593 608 1 0 0 1 0 1 609 624 1 0 0 1 1 0 625 640 1 0 0 1 1 1 641 656 1 0 1 0 0 0 657 672 1 0 1 0 0 1 673 688 1 0...

Page 11: ...rs are made by inserting the signal wires into the appropriate slots and tightening the hold down screws When all ties have been connected insert the mating connectors into the 2083 06 rear panel term...

Page 12: ...he LED stays lit for 5 seconds after code is removed If this LED does not light a problem in the unit or its interconnection may be indicated If an alarm input is activated the green ALARM LED illumin...

Page 13: ...Clear AUX 7 Clears Auxiliary 7 67 Call Shot Clear AUX 8 Clears Auxiliary 8 68 Call Shot Other Pelco Intercept Dome functions Configure Dome Resets dome 72 Call Shot followed by 72 Set Shot Clear scre...

Page 14: ......

Page 15: ...APPENDIX...

Page 16: ......

Page 17: ...R R T T T R R GROUP 1 2 3 4 B W S NO NC C DATA LINE C O M INPUT OUTPUT T R R T T T R R T R R T T T R R T R R T T T R R T R R T T T R R ABCD ABCD ABCD ABCD POWER ALARM CODE OUT 2083 06 COAX CABLE 1995...

Page 18: ...UT C O M INPUT OUTPUT T R R T T T R R T R R T T T R R T R R T T T R R T R R T T T R R ABCD ABCD ABCD ABCD POWER ALARM CODE 2083 W B S B W S 18 AWG SHIELDED TWISTED PAIR BELDEN 8760 OR EQUIVALENT 1650A...

Page 19: ...T R R T T T R R T R R T T T R R GROUP 1 2 3 4 B W S NO NC C DATA LINE IN OUT C O M INPUT OUTPUT T R R T T T R R T R R T T T R R T R R T T T R R T R R T T T R R ABCD ABCD ABCD ABCD POWER ALARM CODE 20...

Page 20: ...R GROUP 1 2 3 4 B W S NO NC C DATA LINE IN OUT C O M INPUT OUTPUT T R R T T T R R T R R T T T R R T R R T T T R R T R R T T T R R ABCD ABCD ABCD ABCD POWER ALARM CODE 2083 06 2150 2350 RS232 PORTS MON...

Page 21: ...UP 1 2 3 4 B W S NO NC C DATA LINE C O M INPUT OUTPUT T R R T T T R R T R R T T T R R T R R T T T R R T R R T T T R R ABCD ABCD ABCD ABCD POWER ALARM CODE OUT 2083 06 T R R T T T R R PELCO INTERCEPTOR...

Page 22: ......

Page 23: ...nio Cork Ireland Aguadilla P R 00690 Declares that the product s listed below Name Type Code Translator Model Number ADS2083 06X complies with the EMC Standards EN55022 Class B EN50082 1 and also comp...

Page 24: ...eight 7 lbs 3 2 Kg Dimensions 3 5 H x 17 W x 7 75 D 89 x 432 x 197 mm An American Dynamics Product Designed and built by Sensormatic CCTV Systems Division One Blue Hill Plaza Pearl River New York 1096...

Reviews: