Safety
1
Chapter 1 - Safety
Please Read the Following Carefully!
This
portion of the manual contains information
regarding all American Eagle manufactured
compressors. Some items contained within
this chapter may not apply to your specific
equipment.
Safety should be the n umber one thought on
every operator’s mind. Three factors should
exist for safe operation: a qualified operator,
well-maintained equipment, and the proper
use of this equipment. The following
information should be read and understood
completely by everyone working with or near
the compressor before putting the unit into
operation.
Please take note that American Eagle, Inc. is
not liable for accidents incurred by the
compressor because of non-fulfillment from
the operator’s side of current rules, laws, and
regulations.
The SRS-40 Rotary Screw Compressor will
provide safe and dependable service if
operated according to instructions. Read
and understand the safety precautions given
in this manual and on the decals attached to
the shields. Failure to do so can result in
personal injury or equipment damage.
Operators and maintenance personnel must
always comply with the safety precautions.
These precautions are given here for your
safety. Review them carefully before operat-
ing the compressor and before performing
maintenance or repairs.
Supervising personnel should develop addi-
tional precautions relating to the specific
work area and local safety regulations.
Precautions
Always wear safety equipment such as gog-
gles, ear plugs and head protection at all
times when operating the compressor.
Do not inspect or clean the compressor while
the power source is connected. Accidental
engagement of the tool can cause serious
injury.
Before performing any maintenance on the
compressor, place a warning tag on the
hydraulic power source or disconnect the
hoses from the compressor motor to prevent
accidental startup of the compressor.
Always connect hoses to the compressor
before energizing the power source. Be sure
all hose connections are tight.
Establish a training program for all operators
to ensure safe operation.
Do not operate the compressor unless thor-
oughly trained or under the supervision of an
instructor.
Do not operate the compressor if it is dam-
aged, improperly adjusted or not completely
or properly assembled.
Never operate the compressor with any of
the guards removed.
Do not attempt to adjust or disable the com-
pressors air pressure relief valve. This valve
protects the compressor in the event of
blockage or air control system malfunction.
The surface of the air compressor and the
plumbing between the compressor and the
cooler may reach temperatures above 150
degrees. Touching these surfaces during
operation can cause burns.
The air taken in by the air compressor must be
free of flammable fumes and vapors.
Compressor speed should not exceed 8000
RPM.
Use and operate this air compressor only in
full compliance with all pertinent O.S.H.A.
requirements and all Federal, State and Local
codes or requirements.
Summary of Contents for SRS-40
Page 2: ...SRS 40 Manual Revisions...
Page 8: ...4 SRS 40 Owner s Manual...
Page 24: ...20 SRS 40 Owner s Manual...
Page 32: ...28 SRS 40 Owner s Manual...
Page 34: ...30 SRS 40 Owner s Manual...