3
INSTALLATION
THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND
SHOULD CONFORM TO THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 AND
LOCAL CODES.
Mount the unit to a secure surface using #8 (3mm) hardware in four places. See the
drawing at the bottom of this page for mounting dimensions. Be sure to allow sufficient
room for the required minimum bend radius of the fiber cable used.
POWER SOURCE
THIS PRODUCT SHALL BE POWERED BY A LISTED CLASS 2 POWER SUPPLY
ONLY.
The unit requires a +12VDC power source for proper operation. The DC input is diode
protected. Current draw is approximately 100mA maximum. In the USA and in Canada
an American Fibertek PS-12 is supplied with this unit. The negative side of the power
input is directly connected to ground. ANSI/NFPA 70 Class 2 wiring is recommended.
POWER CONNECTION
Power is supplied to the unit via a two pin terminal connector. Follow label on unit for
proper orientation of +12 volt dc and ground.
INPUT / OUTPUT CONNECTIONS
The fiber optic connection is made via a ST connector located on the right side of the
unit.
The video input connection is made via a BNC connector on the left side of the unit. The
video input should be connected to an appropriate 75
Ω
baseband video source such as
a camera or a video recorder output. For optimum performance the video cables should
be the shortest length of coax practical.