MTX-8810C-SL STATUS INDICATORS 

The MTX-8810C-SL transmitter provides the following front panel LED status indicators 
to aid in installation and troubleshooting: 

 

DATA

  

These indicators turn green when any data activity is present. An active DATA 1 LED 
indicates data is present at the input /output terminals of the MTX-8810C-SL. An active 
DATA 2 LED indicates the MTX-8810C-SL has seized the data carrier to allow data flow. 
The intensity of the indicators will vary with input / output data patterns, however, the Tx 
and Rx Carrier Detect LEDs will typically appear dimmer than the Sensornet Tx and Rx 
LEDs. The data activity associated with these front panel DATA LEDs are listed below. 
  

DATA 1 TX 

DATA 1 RX 

 DATA 2 TX 

DATA 2 RX 

Sensornet Tx 

Sensornet Rx 

Tx Carrier Detect 

Rx Carrier Detect 

 

OLI 

A bi-color LED indicator monitors the optical input power of the data signal that is being 
received at the MTX-8810C-SL from the MRX-8810C-SL. AC power and optical input 
status associated with this LED are summarized below. 
  

Optical Level Indicator 

AC Power Status 

Optical Status 

Green 

On  

Proper Optical Input Power Present 

Red 

On 

Optical Input Not Detected 

Off 

Off 

Check Power Supply Input 

 

VIDEO 

A bi-color LED indicator is provided for each of the eight video channel inputs. AC power 
and video status associated with each of these LEDs are summarized below. 
 

Video Presence LED 

AC Power Status 

Video Status 

Green 

On  

Proper Input Video Present 

Red 

On 

Input Video Not Detected 

Off 

Off 

Check Power Supply Input 

 

Summary of Contents for MTX-8810C-SL

Page 1: ... Copyright 2005 American Fibertek Inc 1213JD Instruction Manual MTX 8810C SL MRX 8810C SL Eight Channel Video Multiplexer with Bi directional Sensornet Data ...

Page 2: ...ctional Description 3 Installation 3 Power Source 4 Power Connection 4 Input Output Connections 4 Data Configuration 5 MTX 8810C SL Status LED Indicators 6 MRX 8810C SL Status LED Indicators 7 Warranty 8 Service Information 8 ...

Page 3: ...espondingly the MRX 8810C SL receiver converts the optical signal to eight independent video output signals along with the data signals The 8810C SL Series units operate on 9 um singlemode fiber Refer to the data sheets for detailed performance specifications The individual units may be configured for rack mounting or wall mounting depending upon the position of the included mounting hardware INST...

Page 4: ...UT CONNECTIONS The fiber optic connection is made via a FC PC connector located at the back of the unit Be sure to allow sufficient room for the required minimum bend radius of the fiber cable used Video input and output connections are located on the rear of the unit A BNC connector is provided for each channel The video inputs are connected to an appropriate 75Ω baseband video source such as a c...

Page 5: ...of switch 5 these switches must remain in the positions shown below to properly transmit Sensornet data Switch 5 is used to apply a 120Ω termination resistor across the data I O connections These units are shipped with the data input output connections unterminated Move switch 5 to the down position if termination is required for your application ...

Page 6: ...t panel DATA LEDs are listed below DATA 1 TX DATA 1 RX DATA 2 TX DATA 2 RX Sensornet Tx Sensornet Rx Tx Carrier Detect Rx Carrier Detect OLI A bi color LED indicator monitors the optical input power of the data signal that is being received at the MTX 8810C SL from the MRX 8810C SL AC power and optical input status associated with this LED are summarized below Optical Level Indicator AC Power Stat...

Page 7: ...r Detect Rx Carrier Detect OLI 1 A bi color LED indicator monitors the power of the optical input signal that is being received at the MRX 8810C SL from video channels one through four of the MTX 8810C SL AC power and optical input status associated with this LED are summarized below Please note that data is sent as a subcarrier on channel one s video signal Optical Level Indicator AC Power Status...

Page 8: ...R THE FOREGOING WARRANTY THERE IS NO WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR OTHERWISE EXPRESSED OR IMPLIED WHICH EXTENDS BEYOND THE WARRANTY SET FORTH IN THIS AGREEMENT In any event American Fibertek will not be responsible or liable for contingent consequential or incidental damages No agreement or understanding expressed or implied except as set forth in this warranty...

Reviews: