Rev 10/29/13
12
Encoder Error (5.0s)
– Here is where the timer value is set that the
controller will monitor for change in encoder positions prior to stopping
movement of the door and displaying the error “Encoder Error.”
Enable Home Sensor (500)
– Enter Here the position at which the
controller should start looking for the home (fully closed) sensor. The
purpose of this is so the encoder does not stop and zero the encoder
unless it’s close to the floor.
Motor Time Out (20s)
– Here is where the value is set for the
maximum amount of time in Seconds that the motor is allowed to
run in either directions before it will cease moving and display and
error stating “Mtr Timeout.”
Alarm Screen
– This screen will log all input triggers and fault alarms
with a time/date stamp. This is a fault history that can be used for
debugging a faulty operation.