Outputs
It’s important to know the maximum amperage and voltage for the outputs on the PLC.
Maximum output current per relay
3 A at 250 VAC, resistive
Maximum total output current
5 A continuous
Maximum output voltage
275 VAC 30 VDC
_____________________________________________________________________________
Output # Output Description
Q1 Run to Drive – N.O. Tells the drive to operate. If Q1 is energized and Q2 is not, the door
will move in the open direction.
Q2 Close to Drive - N.O. Closes when energized and Q1 Run is energized..
Q3 Fast to Drive – N.O. Energized when the door is operate at is fast speed.
Q4 Quick Decelerate to Drive – N.O. Energized when a safety device is triggered and the door
is closing. This will use the deceleration value of 0 to reverse the drive quickly.
Q5 Door Open - N.O. Energized when the door is fully closed. Customer can connect this to a
security system or something of that nature.
Q6 Door Open – N.O. Energized when the door is fully open. Customer can connect this to a
Green Go light or something of that nature.