background image

Rev 10/29/13 

Next Screen – Displays the Close Slow Down Set point position, in this 

mode these values are not modifiable.   

Next Screen – Displays the Safety Edge Slow Down position, in this mode 

these values are not modifiable.   

.  

Next Screen – Displays the Mid Stop Slow Down position, in this mode 

these values are not modifiable.   

Next Screen – Displays the Mid Stop, Stop position, in this mode these 

values are not modifiable.   

Next Screen – Displays the Safety Edge Bypass position, in this mode 

these values are not modifiable.   

Next Screen – Displays the Motor Time Out, in this mode these 

values are not modifiable.   

M

*

CK

 

Summary of Contents for smart JACK

Page 1: ...Safeties Are Bypassed In Hand Mode Set Up Manual...

Page 2: ...le of Contents Cover Pg 1 Table of Contents Pg 2 Introduction Pg 3 Input Description Pg 4 Output Description Pg 5 Main Menu Description Pg 6 Setup Menu Description Settings Pg 9 12 Setup Menu Descript...

Page 3: ...the door ramps up to full speed decelerated to a slow speed then comes to a stop in the open position this is a smooth motion Once a close command it given the door ramps up to full speed then deceler...

Page 4: ...ly reopen If the loop is active when the door is open it will not close May also initiate automatic closing of the door See Door Operation Setup I7 Auxiliary Open N O Similar to Open Pushbutton I1 exc...

Page 5: ...not the door will move in the open direction Q2 Close to Drive N O Closes when energized and Q1 Run is energized Q3 Fast to Drive N O Energized when the door is operate at is fast speed Q4 Quick Dece...

Page 6: ...the actual position of the door from the encoder Timer Displays the Auto Closer timer set point and will show the timer value timing down when timer is activate V1 5 shows the program version that s i...

Page 7: ...not modifiable Next Screen Displays the Mid Stop Slow Down position in this mode these values are not modifiable Next Screen Displays the Mid Stop Stop position in this mode these values are not modif...

Page 8: ...tates the input is active When it is not darkened this states the input is not active Next Screen Displays the digital input status 2 screen Digital Input Status2 This screen shows the status of digit...

Page 9: ...entered the the corresponding fields Please note the following when in setup menu Press the Ent button then key in the desired set point then press the Ent again PLEASE NOTE AT ANY TIME F2 CAN BE PRE...

Page 10: ...is where the value that the controller waits after the door is open before it closes automatically is entered Please note that the Auto Close Timer is only active when selected to Auto Auto Close Time...

Page 11: ...tely 100 counts to allow for this Mid Stop Slow Down Move the door to the desired mid stop slow down position then look at the value of the encoder Enter that value into this field keeping in mind tha...

Page 12: ...ome fully closed sensor The purpose of this is so the encoder does not stop and zero the encoder unless it s close to the floor Motor Time Out 20s Here is where the value is set for the maximum amount...

Page 13: ...point in this mode Also make sure to start this function when the door is in the fully closed position and the home sensor is activated I7 Open Speed Hertz 45 00 Here is where the value is set in Her...

Page 14: ...exclusive property of C W Automation Inc and cannot be used in whole or part without expressed written consent LOCATION DN BY CK BY SCALE DRAWING NUMBER NO REVISION BY DATE PROJECT NTS Drawing Tolera...