Banner- 110 VAC

Wiring Diagram 

1-1-05

Note:

This wiring Diagram is set up for Supralift & Magnelift Air-Powered Operators only.

2005 ©

1-800-233-1487

www.carwashdoors.com

Banner Photoeye Sensors

Emitter

Blue- 110V

From Transfomer

Brown- 

Common On

110V Transformer

Receiver

Blue- 110V

From Transfomer

Brown- To Relay

110V Relay

Normally Closed

28

Summary of Contents for Supralift II

Page 1: ...Air Powered Operator Installation Manual 1 1 2020 American Garage Door Supply Inc 1 800 233 1487 1...

Page 2: ...tem Installation should be performed by a trained professional 3 Follow equipment manufacturer s recommendations on tools ladders and other equipment used for installation 4 Any air powered opener mus...

Page 3: ...ch pushes the piston rod assembly down The drive chain is attached to the top of each piston rod and loops over the sprocket on the doors torsion shaft On the open signal compressed air drives the ope...

Page 4: ...Sample Installation Pictures Top of Cylinder View Top Assembly View Chain Sprocket View Bottom of Cylinder View Flow Control View Control Box View 4...

Page 5: ...41 x 12 Tooth SS Sprocket 1 4 x 2 SS Key 900 3 8 x 1 4 NPT Push in Fitting Flow Control Kit 2 ea 1 ea 1 ea 4 ea 1 ea HARDWARE PACKAGE Part Number TBLTS1458 NUTFS14 SLAC SLSC12 SLJNUT SLSTBS CN41 CMLWP...

Page 6: ...Components Identification Aluminum Collar with Set Screw Aluminum Collar Lock Nut Chain Master Links Sprocket with Set Screws 1 4 Key Push in Fitting Turnbuckle Track Bolt Nut Cylinders 6...

Page 7: ...set screws at this time Slide sprocket near end bearing plate of the door Figure 2 Step 6 With the door closed hang the operator by the chain assembly over the sprocket onto the torsion shaft Keep th...

Page 8: ...e piston rod on the cylinder closest to the wall close cylinder all the way down until the piston bottoms out in the cylinder then raise the piston rod 1 1 1 2 upward and tighten the set screw on the...

Page 9: ...w Driver Phillips Screwdriver Hand Wrenches 1 4 7 16 1 2 9 16 5 8 3 8 Socket Set 7 16 1 2 9 16 5 8 Electric Impact or Drill with 3 8 and 7 16 Sockets 1 4 drill bit Small Pipe Wrench Wire Cutters Teflo...

Page 10: ...Components Identification Control Box Flow Control 2 1 2 Nipple Porex Muffler 1HHGOH 9DOYH Filter Regulator Shut off Valve Assembly and Inline Dryer Optional 10...

Page 11: ...viously installed push in fitting on the bottom of the cylinders to the push in fittings located on the top of the flow controls Plumb the line from cylinder nearest the jamb to the close and the line...

Page 12: ...the regulator adjustment knob FORFNZLVH slowly until it reaches approximately 60 PSI Recommended air pressure between 45 PSI and 70 PSI Step 3 Plug in 110 volt power cord located on the bottom of the...

Page 13: ...l slow the travel speed of the door The check ball in each valve allows each cylinder to breath freely as the piston is draw up mechanically by the chain on the reverse cycle Caution The Supralift ope...

Page 14: ...62 PSI is common Heavier doors may need to have the pressure increased but if you must exceed 90 PSI you probably have a door problem Replacing the filter in the regulator is recommended every 6 mont...

Page 15: ...g and Limits Opener to be equipped with a 1 x 12 tooth driven sprocket for the door shaft with 41 chain Limits to be set by mechanical means by adjustment of the pistons and aluminum collar Operator s...

Page 16: ...10 high door under normal operating conditions will open and close 3 times a minute Stroke Lengths of Cylinder 8 Opener 47 1875 10 Opener 59 1875 12 Opener 71 1875 14 Opener 83 1875 16 Opener 95 1875...

Page 17: ...17...

Page 18: ...1 2 3 4 5 6 7 8 9 10 11 12 13 8 14 5 7 9 15 16 17 18 19 20 21 22 23 24 27 25 26 28 Supralift Parts Diagram 18...

Page 19: ...p SS Track Bracket SS Bottom Plate Carriage Bolt 5 16 x 3 4 SS Flanged Hex Nut 5 16 18 SS Hex Head Bolt 5 16 x 5 8 SS Wear Sleeve Ring Piston Seals Seal Kit Supralift Piston Rod 8 Supralift Piston Rod...

Page 20: ...Photo Eye Base Black White Black White Black Receiver White Black White Transmitter 20...

Page 21: ...GGLQJ 6HFRQG 6HW RI 3KRWR HV ZLWK ORVH WLPHU 7KH QG VHW RI 3KRWR H HV ZLUHV GLUHFWO WR WKH 3LQ ORFN DV VKRZQ KHUH LULQJ WR QG 3 1 ORFN 5HG HOORZ 5HG HOORZ 21...

Page 22: ...Control Box Wiring Diagram 1 800 233 1487 Old Style 22...

Page 23: ...photo eye The Door should continue down and close If the door reverses check connections and repeat the process White Wire is Not Used Control Box Terminal Strip Wiring a Magnetic Contact Switch MCS T...

Page 24: ...m Wiring Eyes Wire numbered terminals on contact block to appropriate numbers listed on Receiver Transmitter and Terminal Strip Once wired plug in amplifier to 11 pin socket located on contact block C...

Page 25: ...ndard Control Box Macromatic Timer Wiring Diagram 1 2 3 4 5 6 7 8 9 1 0 1 1 1 8 Seconds Time ranges from 1 8 seconds to 180 seconds 30 60 90 120 150 180 Timer Toggle Switch OPTIONAL Wiring Diagram Wir...

Page 26: ...timer to work Use 5 and 7 on the contact block for connection to your incoming signal This signal should be a continuous signal with the same voltage as the timer primary power For 120VAC one shot ti...

Page 27: ...ote This wiring Diagram is set up for Supralift Magnelift Air Powered Operators only 1 800 233 1487 www carwashdoors com Banner Photoeye Sensors Emitter Blue 24V Brown Common Receiver Blue 24V Brown T...

Page 28: ...t up for Supralift Magnelift Air Powered Operators only 2005 1 800 233 1487 www carwashdoors com Banner Photoeye Sensors Emitter Blue 110V From Transfomer Brown Common On 110V Transformer Receiver Blu...

Page 29: ...er in lieu of all other warranties written oral or implied including any warranty of merchantability or fitness for purpose and all other obligations or liabilities on the part of the Company The Comp...

Reviews: