RM4200 Series User Guide
RM4210 & RM4211 Installation
19
N
OTE
:
American Innovations recommends using AI part number 211061-000 (Belden 5308UE), or equivalent,
for wiring inputs. To ensure a clean stable reading, keep field wiring as short as possible and use shielded twisted
pair wire such as Alpha 2463C.
Complete the following steps to install the RM4211 on a coupon test station.
1
Remove the protective cover over the test station head.
2
Connect wiring harness individual wires to the respective test points on the test station.
Figure 2-12. Wiring Harness Leads
The wires are color-coded and labeled for use with a Triton® coupon test station. If connecting to
another type of test station, note the following:
The blue and red Test Cpn leads must be on the same connection.
3
For Triton coupon test stations only
: disconnect the wire from the
Switch
.
4
Slip the test station adapter over and onto the test station. Rotate clockwise to secure the adapter onto
the test station.