RM4200 Series User Guide
Configuration
39
Editing Settings for Coupon, Transducer, and Instant Off
The
Settings
window includes settings for the following components:
•
Test and Triton coupons
— coupon size, AC current density alarm, and an alarm value.
•
AC Drain Current Transducer Settings:
–
Input Max
– maximum transducer voltage output.
–
Transducer
– corresponding transducer measurement value at maximum transducer voltage
output.
•
Instant Off
— the wait time to take an instant off voltage measurement after cathodic protection has
been interrupted through an internal relay.
Complete the following steps to set the settings for coupon, transducer, and instant off:
1
Click
Settings
. The
Settings
window displays.
Figure 3-21. Settings for Coupon, Transducer, and Instant Off
2
For either the Test Coupon or Triton Coupon:
a
Edit the
Coupon Size
field for your coupon.