Page 27
200 Series 36V
15312
Resistor
Remove the resistor from one post of the contactor. The side that is powered from
the battery is recommended.
Use “Ω” setting on the meter.
Place one probe on the free end of the resistor and one on the other post. The
reading should be approximately 680 ohms.
If this does not happen, replace the resistor.
Note: Additionally, a hot resistor across the Contactor indicates a failed controller.
Controller Evaluation
If it is suspected that the motor controller is bad, perform these checks before
replacing.
(-) Probe Placement
(+) Probe Placement
and Resistance
Reading
Contactor
Resistor Removed
from this Post
To Controller