ENGLISH / A-35
FORM NO. 56041720 - 7730 -
A-35
MAINTENANCE
WARNING!
*
Do not remove the battery from the machine if there is waste in the solution tank.
*
Hydrogen gas is formed during the charging operation and is explosive! Only charge batteries in a well-ventilated area with the lid
open. Avoid any open
fl
ame or electrical sparks. Pulling out the charger plug, with the charger still on, will cause an arc and must
be avoided.
*
Batteries are heavy. Use lifting device with speci
fi
ed rated capacity.
*
Always remove jewelry, wear protective clothing, and face protection when working near batteries.
*
Lead acid batteries generate gases, which cause explosions. Keep sparks and
fl
ames away from batteries charge the batteries only
in area with good ventilation. NO SMOKING!
*
To prevent an explosion, disconnect the AC plug from the receptacle before connection or disconnect the DC plug on the charger.
*
The battery box can slide off a forklift and cause severe personal injury or damage to equipment. Ensure that the battery box is
properly secured to the forks of the forklift during transport, drive and stop with caution.
FIGURE 63
FIGURE 64
FIGURE 65
FIGURE 66
BATTERY REMOVAL
When removing batteries
1. Fig. 63 & 64. Lift the machine front cover to access battery compartment and rotate the battery lever (A) to the right.
2. Fig. 65. Unplug the battery power connector from the machine power connector.
3. Fig. 66. Lift the battery out using a 2000 LB. (907 KG) capacity lifting device.