8
American-Lincoln
SC7750 IC
YOUR SC7750 IC MACHINE HAS BEEN SHIPPED COMPLETE, BUT DO NOT ATTEMPT TO OPERATE
WITHOUT FOLLOWING THESE INSTRUCTIONS.
PREPARING THE MACHINE FOR OPERATION
1.
Connect and tighten battery cables.
2.
Fill the tank with REGULAR GRADE gasoline. (Diesel fuel if equipped with diesel engine.)
WARNING
Never fill the tank while the engine is running. Always be sure the gasoline container and sweeper are electri-
cally connected before pouring gasoline. This can easily be done by providing an insulated wire (permanently
attached to container) with a battery clip on the other end.
3.
Check engine crankcase oil level. Although properly lubricated at the factory, check before starting the
engine. No special break in oil is used and recommended number of operating hours before the initial oil
change is the same as normal. See Maintenance.
4.
Check radiator coolant level. Permanent type antifreeze is added at the factory to provide protection to
approximately -35°F (37°C). To retain this protection level, always add ½ part water to ½ part antifreeze.
5.
Check oil level in the hydraulic reservoir located at the center of the machine beside the engine. The oil
fill level should be halfway on sight glass. If oil is needed, add HYDRAULIC FLUID ONLY, automatic
transmission fluid FORD type “F.” After the first 50 operating hours, service must be performed on your
engine to ensure future high performance and trouble-free operation. See Maintenance.
NOTE
After the first 50 operating hours, service must be performed on your engine to ensure
future high performance and trouble-free operation. See Maintenance.
MACHINE PREPARATION
C1694c
FIGURE 1