StorTrends® 1300 User’s Guide (StorTrends iTX version 2.7)
16
Checking the Drive Bay Setup
Next, you should check to make sure that the peripheral drives, the SATA drives and
SATA backplane have been properly installed and all connections have been made.
Step Description
Step 1: Accessing the
drive bays
All drives are accessible from the front of the server. For servicing
the DVDROM drive, you will need to remove the top chassis cover.
The SATA disk drives can be installed and removed from the front
of the chassis without removing the top chassis cover.
Step 2: DVD-ROM
drive
A slim DVD-ROM drive should be preinstalled in your server.
Step 3: Check the
SATA disk drives
Depending upon your system's configuration, your system may have
one or more drives already installed.
Step 4: Check the
airflow
Airflow is provided by three sets of 4-cm fans (each set of fans
consists of two fans that are mounted back to back). The system
component layout was carefully designed to direct sufficient cooling
airflow to the components that generate the most heat. Note that all
power and data cables have been routed in such a way that they do
not block the airflow generated by the fans.
Step 5: Supplying
power to the system
The last thing you must do is to provide input power to the system.
Plug the power cords from the power supply modules into a high-
quality power strip that offers protection from electrical noise and
power surges. It is recommended that you use an uninterruptible
power supply (UPS) source.
Summary of Contents for ManageTrends 2.7
Page 18: ...StorTrends 1300 User s Guide StorTrends iTX version 2 7 xviii...
Page 24: ...StorTrends 1300 User s Guide StorTrends iTX version 2 7 6...
Page 33: ...Chapter Two Chassis Set Up 15 Accessing the Inside of the System...
Page 60: ...StorTrends 1300 User s Guide StorTrends iTX version 2 7 42...
Page 64: ...StorTrends 1300 User s Guide StorTrends iTX version 2 7 46...
Page 70: ...StorTrends 1300 User s Guide StorTrends iTX version 2 7 52...
Page 100: ...StorTrends 1300 User s Guide StorTrends iTX version 2 7 82...
Page 106: ...StorTrends 1300 User s Guide StorTrends iTX version 2 7 88 Control Panel...
Page 236: ...StorTrends 1300 User s Guide StorTrends iTX version 2 7 218...
Page 256: ...StorTrends 1300 User s Guide StorTrends iTX version 2 7 238...
Page 277: ...Appendix E Replication Overview 259 Snap Assisted Replication Navigating with ManageTrends...
Page 281: ...Appendix E Replication Overview 263 Replication SAR view Primary Box SAR view Secondary Box...
Page 285: ...Appendix E Replication Overview 267 After Failover Operation in Secondary Box...
Page 300: ...StorTrends 1300 User s Guide StorTrends iTX version 2 7 282...
Page 308: ...StorTrends 1300 User s Guide StorTrends iTX version 2 7 290...
Page 330: ...StorTrends 1300 User s Guide StorTrends iTX version 2 7 312...
Page 356: ...StorTrends 1300 User s Guide StorTrends iTX version 2 7 338...