AP20BCF200-3-XL Installation & Operations Manual
P: (800) 327-3015
E: Service@americanpanel.com
Factory Presets Automatic Mode - Quick Reference Chart
Cycle
Setting
Low Air
Part 1
High Air
Part 1
Breaking
Temp.
Low Air
Part 2
High Air
Part 2
End Food
Temp.
Low Air
Holding
High Air
Holding
Soft
28˚F
35˚F
NA
NA
NA
40˚F
35˚F
42˚F
Hard (Chillers Only)
10˚F
20˚F
60˚F
28˚F
35˚F
40˚F
35˚F
42˚F
Hard (Chillers &
Freezers)
0˚F
0˚F
60˚F
28˚F
35˚F
40˚F
35˚F
42˚F
Shock Freeze
-25˚F
15˚F
NA
NA
NA
0˚F
-4˚F
3˚F
Thaw
42˚F
50˚F
NA
NA
NA
32˚F
35˚F
42˚F
Factory Presets Manual Mode - Quick Reference Chart
Cycle
Setting
Low Air
Part 1
High Air
Part 1
Time
Part 1
Low Air
Part 2
High Air
Part 2
Time
Part 2
Low Air
Holding
High Air
Holding
Soft
28˚F
35˚F
NA
NA
NA
90 Min
35˚F
42˚F
Hard (Chillers Only)
10˚F
20˚F
60 Min
28˚F
35˚F
60 Min
35˚F
42˚F
Hard (Chillers &
Freezers)
0˚F
0˚F
60 Min
28˚F
35˚F
60 Min
35˚F
42˚F
Shock Freeze
-25˚F
15˚F
NA
NA
NA
240 Min
-4˚F
3˚F
Thaw
42˚F
50˚F
NA
NA
NA
Set at Start
35˚F
42˚F