background image

Blast Chiller

 (Modular) - 

AP26BC-3T

Controller

Dimensions

5800 SE 78th St. Ocala, FL 34472-3412

T:

 1.800.327.3015 • 352.245.7055 

www.americanpanel.com

AP26BC-3T_Spec  2/21

Options and Accessories

Specifications

INSTALLATION

: A detailed installation manual is provided. It must be 

carefully followed to ensure proper operation and to protect your rights 

under the warranty.

•  Cabinet Sanitation

: The ultraviolet system sanitizes all metal surfaces within 

the cabinet in a preset time of 30 minutes.

•  USB HACCP Interface

: Use a standard USB thumb drive to easily download 

HACCP data. The information recorded includes date, time, cycle identification, 

recipe name, and product core temperature at prescribed intervals.

•  Wi-Fi Connectivity

: Supported functions include peer-to-peer connectivity, 

remote monitoring over the local network, HACCP data download and alarm 

notifications via e-mail.

•  4” Insulated Floor Panels

: Allow for height increase to detail shown above.

•  Remote Refrigeration

: RCU15BC, available in air cooled and water cooled 

configuration

•  Prison Security Package
•  Extra Food Probes

: Three probes is standard, up to 1 additional food probes 

can be provided.

•  Mobile Racks

: Model APR13-26 will accommodate 26 full size steam table 

pans (12”x20”x2 1/2”) or 13 full size sheet pans (18”x26”).

•  Reversed Cabinet

: The entire assembly is manufactured so that it is a mirror 

image of the cabinet shown above.

•  Second Door

: For pass-thru operation (increases depth by 16” for external 

ramp)

•  Alternate refrigerant configuration available
•  Right hand hinge available

Soft Chilling:

 The air temperature is held in the range of 28°F to 

35°F, ideal for delicate food items. The chilling cycle is completed 

when the food core temperature reaches 38°F.

Hard Chilling

: The air temperature is lowered to and held  within 

a range of 10°F to 20°F. When the food core temperature reaches 

60°F, the air temperature rises to a range of 28°F to 35°F. The 

chilling cycle is completed when the food core temperature 

reaches 38°F.

Shock Freeze

: Not available on AP26BC-3T 

Quick Start

: Programmable single touch button to start a cycle. 

Used for the most popular settings for the customer. This allows 

for starting any chilling or freezing cycle with one touch..

ADDITIONAL FEATURES:

Thawing (Optional):

 Not available on AP26BC-3T

Holding:

 At the end of any cycle, the unit will automatically switch 

to a holding mode which will keep the food at holding temperature 

until the cycle is stopped. 

Defrost:

 A heated defrost cycle is included within the unit’s 

controller programming.

Product Names:

 Store up to 150 product names. 

Electrical

Refrigeration Connections

Required Condensing Unit

Model

V

Hz

PH

A

MCA

MOPD

Liquid Line

Suction Line

Type

Ref

BTU/HR*

Ship Weight

AP26BC-3T

208

60

1

22.7

30

30

3 x 1/2”

3 x 1 1/8”

Med.Temp. 

40˚F - -10˚F

R404A

102,000

3,349 lbs.

* - Rating at 14˚F SST and 105˚F cond. temp. 