The  main  menu  is  accessed  by  pressing  the

 

  -button  until  the  display  starts  flashing. 

Browse  through  the  menu  by  pressing  the 

  -button  , 

  -button  , 

  -button  or 

  -button.  Press  the  Enter-button  in  order  to  select  the  desired  menu.  You  can  change  the 

selection  by  pressing  the  the 

  -button  , 

  -button  , 

  -button  or 

  -button. 

Confirm every selection by pressing the

  -button. You can leave every mode by pressing the 

-button.  The  functions  provided  are  described  in  the  following  sections.  it  will  exit  from 

flash 10 seconds after the last keypress. Press this key under edit mode, . The functions provided 
are described in the following sections. 

 

To  access  the  display  menu  via  the  internal  battery,  press the  DC  switch  button  for 
2seconds; To shut off the display immediately, choose the commend " Reset All" menu and 
press  "Enter"  button, otherwise,  the  display will  automatically  switch  off  about  1 
minute from last button press. 
 

Fu

n

ct

io

n

 

 

Set Dmx Address 

Dmx Value   

Slave Mode 

Auto Program 

Sound Control 

A001~AXXX 

PAN…… 

Slave1,Slave2,Slave3 

Master / Alone 

Master / Alone 

DMX address setting 

DMX value display 

Slave setting 

Auto program 

Music control 

In

fo

rm

at

io

n

 

Time Information 

Current Time 

Total Run Time 

Last Run Time 

Lamp Hours 

Lamp Off Time 

LastRun Password 

Clean Last Run 

LampTime    Password   

Clean Lamp Time 

XXXX(Hours) 

XXXX(Hours) 

XXXX(Hours) 

XXXX(Hours) 

XXXX(Minute) 

Password=XXX 

ON/OFF 

Password=XXX 

ON/OFF 

Power on running time 

Fixture running time 

Fixture Last times clear 

Lamp running time 

Lamp off time 

Timer Password 

038

 

Clear Fixture Last time 

Lamp Password =”038” 

Clear lamp time 

Temperature Info 

Head Temperature 

XXX

/

 

Temperature in the head 

Software Version 

Ver x.x……

 

Software version 

La

m

p

 C

o

n

tr

o

Lamp On/Off 

Automatic On 

Lamp On via DMX   

Lamp Off via DMX 

Max On at Temp. 

Lamp Off Temp. 

ON/OFF 

ON/OFF 

ON/OFF 

ON/OFF 

20~79

,45

 /68~174

 113

 

80~139

, 130

 /176~282

, 266

 

Lamp on/off 

Lamp on/off    Power on 

Lamp on via DMX 

Lamp off via DMX 

Lamp restart at temp. 

Lamp off at temp. 

Summary of Contents for Neo Plat 15R Beam

Page 1: ...Products http www americanpro audio com User Manual KEEP THIS MANUAL FOR FUTURE NEEDS Contents...

Page 2: ...19 8 4 PERSONALITY 19 8 4 1 Status Settings 19 8 4 2 Service setting 21 8 4 3 Fans Control 22 8 4 4 Display Setting 22 8 4 5 Temperature C F 22 8 4 6 Initial Status 23 8 4 7 Reset Default 23 8 5 Reset...

Page 3: ...motion Movement Pan 540 630 540 90 offset optional Tilt 270 Speed of pan tilt movement adjustable Scan position memory auto reposition after unexpected movement Colors Basic color wheel with 8 dichro...

Page 4: ...If the device has been exposed to temperature changes due to environmental changes do not switch it on immediately The arising condensation could damage the device Leave the device switched off until...

Page 5: ...in discotheques theatres etc the device was designed for indoor use only This fixture is only allowed to be operated with the max alternating current which stated in the technical specifications in t...

Page 6: ...reached the maximum rated life and should be replaced immediately After the lamp has flickered for about five minutes it should strike normally allowing the fixture to be used temporarily until a rep...

Page 7: ...Otherwise it is likely to trigger the protecting firmware to make the replaced lamp close itself automatically Please remember the lamp is not a hot restrike type you must wait for approximately 10 m...

Page 8: ...tion of all installation material and the device If you lack these qualifications do not attempt the installation yourself Improper installation can result in bodily injury T he electric connection m...

Page 9: ...s on the bottom of the device Tighten the quick lock fasteners fully clockwise c Install the second Omega holder d Pull the safety rope through the holes on the bottom of the base and over the trussin...

Page 10: ...XM907 V2 2 0 A 9 Layout Drawings...

Page 11: ...stallation material being used and periodic safety inspection of all installation material and the fixture If you lack these qualifications do not attempt the installation yourself Improper installati...

Page 12: ...nt out from the DMX controller The allocation of this starting address is achieved by setting the correct number on the display located on the base of the device You can set the same starting address...

Page 13: ...ut 1 minute from last button press Function Set Dmx Address Dmx Value Slave Mode Auto Program Sound Control A001 AXXX PAN Slave1 Slave2 Slave3 Master Alone Master Alone DMX address setting DMX value d...

Page 14: ...ey Lock 02 60m 05m ON OFF ON OFF Display shutoff time Reverse 180 degree Key Lock Temperature C F Celsius Fahrenheit Temperature switch between Initial Status PAN XXX Initial effect position Reset Def...

Page 15: ...annel The display automatically shows the channel with a value changing 1 Access the main menu 2 Tap the Up Down button until DMX Value is displayed 3 Press ENTER the display will show DMX Value 4 Tap...

Page 16: ...Press ENTER to confirm or press MODE ESC to return to the main menu Total Run Time With this function you can display the running time of the device The display shows XXXX XXXX stands for the number o...

Page 17: ...y will show XXXX Minute 5 Press ENTER to confirm or press MODE ESC to return to the main menu LastRun Password With this function you can display the timer password The time password is 038 1 Tap MODE...

Page 18: ...you can display the temperature on the display board of the base near CMY filter in Celsius 1 Tap MODE ESC button access the main menu Tap the Up Down button until Information is displayed Press ENTER...

Page 19: ...e display will show Automatic On Press ENTER the display will show Automatic On 2 Press Up Down the display will show OFF or ON 3 Press ENTER to confirm or press MODE ESC to return to the main menu 8...

Page 20: ...f the lamp be shut off automatically due to over heat it can not be striked again automatically it must be turned on again by manually 8 4 PERSONALITY 8 4 1 Status Settings Address via DMX With this f...

Page 21: ...e display will show ON 5 Press ENTER to confirm or press MODE ESC to return to the main menu Pan Degree With this function you can select pan degree for 630 or 540 1 Tap MODE ESC button access the mai...

Page 22: ...ess ENTER to confirm or press MODE ESC to return to the main menu Hibernation Standby mode The lamp and step motors will be power off if the fixture stay without DMX signal for 15 mins Factory default...

Page 23: ...ress Up Down the display will show ON 5 Press ENTER to confirm or press MODE ESC to return to the main menu Key Lock With this function you can activate the automatic keylock status If this function i...

Page 24: ...Up Down the display will show Reset Pan Tilt Reset Colors Reset Gobos Reset Shutter Reset Others 3 Press ENTER to confirm or press MODE ESC to return to the main menu 8 6 Effect Adjust 8 6 1 Test Chan...

Page 25: ...eturn to the main menu 8 8 Edit program 8 8 1 Select Programs With this function you can select the program for the Program Run 8 8 2 Edit Program With this function you can edit the internal programs...

Page 26: ...select which Slave program is to be sent Selection Part 1 means that the Slave unit runs the same program as the master units Press the Enter button to confirm Press the MODE ESC button in order to r...

Page 27: ...1 30 44 Color 2 45 59 Color 3 60 74 Color 4 75 89 Color 5 90 104 Color 6 105 119 Color 7 120 127 Color 8 128 189 Forwards rainbow effect from fast to slow 190 193 No rotation 194 255 Backwards rainbo...

Page 28: ...ting gobo indexing Fine 0 255 Fine indexing 4 4 11 Fixed Gobos 0 7 Open hole 8 15 Gobo 1 16 23 Gobo 2 24 31 Gobo 3 32 39 Gobo 4 40 47 Gobo 5 48 55 Gobo 6 56 63 Gobo 7 64 71 Gobo 8 72 79 Gobo 9 80 87 G...

Page 29: ...m Prism Gobo macros 0 31 Open 32 127 Rot Prism 128 135 Macro 1 136 143 Macro 2 144 151 Macro 3 152 159 Macro 4 160 167 Macro 5 168 175 Macro 6 176 183 Macro 7 184 191 Macro 8 192 199 Macro 9 200 207 M...

Page 30: ...14 22 Lamp on off reset internal programs 0 19 colour change normal 20 29 colour change to any position 30 39 colour gobo change to any position 40 59 Lamp on 60 79 Lamp switch off 80 84 All motor re...

Page 31: ...of the fixture if the head s magnetic indexing circuit malfunctions sensor failed or magnet missing or the stepping motor is defective or its driving IC on the main PCB The TILT movement is not locate...

Page 32: ...od condition and extend the life time we suggest a regular cleaning to the lights 1 Clean the inside and outside lens each week to avoid the weakness of the lights due to accumulation of dust 2 Clean...

Page 33: ...XM907 V2 2 0 A 32 Remark errors and omissions for every information given in this manual excepted All information is subject to change without prior notice...

Reviews: