12
4580 N. Walnut Rd., N. Las Vegas, NV 89081 | 13592 Desmond St., Pacoima, CA 91331 | tel: 818.897.0808 | 888.753.9898 | www.AmericanRangeHome.com
INSTALLATION
STEP THREE: CONNECT GAS and ELECTRICAL SUPPLY
I. Connect the gas supply.
NOTE:
Before placing appliance into operation, always check for gas leaks. This must be performed by your dealer, a qualified
licensed plumber, or gas service company
J. Connect the electrical supply.
F
A
B
C
B
D
E
F
A. Gas pressure regulator.
B. Adapter (must have 1/2" male pipe thread).
C. Flexible connector.
D. Manual gas shut-off valve.
E. 3/4" or 1/2" gas supply.
F. Use pipe-joint compound.
To avoid risk of electrical shock, personal injury or death; leak testing of the appliance must be conducted
according to the manufacturer’s instructions. Before placing appliance in operation, always check for gas
leaks with soapy water solution.
DO NOT USE AN OPEN FLAME TO CHECK FOR GAS LEAKS
IMPORTANT
– This appliance is equipped with a three-prong grounding plug for your protection against possible electric
shock hazard. Plug it only to a dedicated, grounded three-prong electrical outlet. It is the responsibility of the customer to
make sure the proper type of outlet is installed. Do not, under any circumstances, ground to a gas pipe.
The electrical service in the building must be equipped with a properly grounded three-prong receptacle,
in accordance with local codes, or in the absence of local codes, with the National Electrical Code, ANSI/
NFPA 70, or in Canada – to Canadian electrical codes, CSA C22.2.
DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM THIS PLUG
I
J
!
WARNING
!
DANGER