J30
BARRIER FREE
© 2008 AS America Inc.
31"
(787mm)
SUGGESTED
32-7/8"
(835mm)
32-7/8"
(835mm)
9-1/4
(235mm)
18-1/2
(470mm)
22-7/8
(581mm)
FINISHED WALL
OR SPLASHBACK
8"
(203mm)
1-1/4" O.D. TAILPIECE
1-1/4" O.D. WASTE
FINISHED FLOOR
*
10-3/4"
(273mm)
*
12-7/8"
(327mm)
COUNTERTOP
(BY OTHERS)
SEALING
COMPOUND
1-1/8
(29mm)
8-1/2
(216mm)
OPTIONAL
3/4
(19mm)
SUPPLIES
AS REQ'D
1-3/4" DIA.
STD. DRAIN
OUTLET
3-1/4"
(83mm)
8
(203mm)
4
(102mm)
24
(610mm)
6
(152mm)
MAX.
BARRIER FREE
CLEARANCE
27
(686mm)
MIN.
8
(203mm)
MIN.
9
(229mm)
MIN.
DRAWING FOR
DIMENSIONAL
PURPOSES ONLY.
IT IS NOT AN EXACT
REPRESENTATION.
Standard Collection
®
COUNTERTOP SINK
FIRECLAY
Standard Collection
®
COUNTERTOP SINK
• Classically-styled oval countertop sink
• Made from fireclay china
• Front overflow
• Self-rimming with cutout template supplied
•
Design matched to Standard Collection
®
toilet
and fixtures
❏
0293.004
Faucet holes on 4" (203mm) centers
❏
0293.008
Faucet holes on 8" (102mm) centers
(illustrated)
Nominal Dimensions:
22-7/8" x 18-1/2"
(581 x 470mm)
Bowl sizes:
15-3/4" (400mm) wide
11-1/4" (286mm) front to back
6-1/2" (159mm) deep
Compliance Specifications -
Meets or Exceeds the
Following Specifications:
• ASME A112.19.9M for
Non-Vitreous Ceramic Fixtures
• CAN/CSA B45 Series
MEETS THE AMERICAN DISABILITIES ACT GUIDELINES AND
ANSI A117.1 ACCESSIBLE AND USABLE BUILDINGS AND
FACILITIES - CHECK LOCAL CODES.
Install lavatory 864mm (34") from finished floor.
Lavatory installed 51mm (2") minimum from front edge of countertop
provides 686mm (27") knee clearance area.
To Be Specified:
❏
Color:
❏
White
❏
Linen
❏
Standard Collection Faucet: 8" spread faucet
No. 2881
❏
Standard Collection Faucet: 4" spread faucet
Nos. 2471, 2171, or 2071
❏
Faucet Finish: Chrome or Satin
❏
Supplies:
❏
1-1/4" Trap:
NOTES:
*
DIMENSIONS SHOWN FOR LOCATION OF SUPPLIES AND “P" TRAP
ARE SUGGESTED.
FOR COUNTERTOP CUTOUT AND INSTALLATION INSTRUCTIONS USE
TEMPLATE SUPPLIED WITH SINK.
FITTINGS NOT INCLUDED WITH FIXTURES AND MUST BE ORDERED
SEPARATELY.
SEALING COMPOUND SUPPLIED BY OTHERS.
IMPORTANT:
Dimensions of fixtures are nominal and may vary within the
range of tolerances established by ANSI Standard A112.19.9M.
These measurements are subject to change or cancellation. No responsibility
is assumed for use of superseded or voided pages.
Revised 2/08