background image

755741-100 EN

3

SPECIFICATIONS:

SIDE VIEW

DRAIN / OVERFLOW

END VIEW

L

H

W

C

A

B

J

GENERAL SPECIFICATIONS FOR GREEN TEA BATH TUBS

A 16" 

(406mm)

B 11-1/2" 

(292mm)

A 16" 

(406mm)

B 11-1/2" 

(292mm)

3-1/2" 

(89mm)

3-1/2" 

(89mm)

C 19" 

(483mm)

C 19" 

(483mm)

58-1/2" 

(1485mm) 

x 34-1/2" 

(876mm)

70-1/2" 

(1791mm) 

x 34-1/2" 

(876mm))

60-3/16" 

(1529mm)

x 34-1/2" 

(876mm)

72-3/16" 

(1834mm)

x 34-1/2" 

(876mm)

L  60" (1524mm) 

W 36" (914mm) 

H  21" (533mm) 

L  72" (1829mm)  

W 36" (914mm) 

H  21" (533mm)

54 lb.

(24 kg.) 

78 lb.

(35 kg.)

487 lb. (221 kg)/

32 lb./sq.ft.

(159 kg/sq.m)

628 lb. (285 kg)/

35 lb./sq.ft.

(170 kg/sq.m)

52 gal.

(197 l.)

66 gal.

(250 l.)

Description

Drain /

Overflow

Cut Out

Pier 

G x F

Rough-In

Recess 

E x D

Tub Edge to

Centerline

Overflow: J

Weight with

Water / Floor

Loading

Product

Weight

Gallon to

Overflow

Height to

Underside 

of Deck 

Edge: C

Dimensions

L-W-H

3571

 Green Tea

5' x 36"

3573

Green Tea

6' x 36"

60"

(1524mm)

36"

(914mm)

11-1/2"

(292mm)

OUTLINE OF CUTOUT 58.5" x 34.5" (1486 x 876mm)

14-3/4"

(375mm)

CUTOUT IN FLOOR FOR DRAIN

9"

(229mm)

CL

19"

(483mm)

21"

(533mm)

INTEGRAL FEET

ROUGH

FLOOR

4" 

(102mm)

 2"

(51mm)

C/L OF OVERFLOW

LEVELING STRINGER NOT 

FOR SUPPORT 

72"

(1829mm)

36"

(914mm)

11-1/2"

(292mm)

14-3/4"

(375mm)

CL

9"

(229mm)

19"

(483mm)

 2"

(51mm)

OUTLINE OF CUTOUT 70.5 x 34.5 (1780 x 876mm)

21"

(533mm)

4" 

(102mm)

INTEGRAL FEET

ROUGH

FLOOR

C/L OF OVERFLOW

LEVELING STRINGER NOT 

FOR SUPPORT 

CUTOUT IN FLOOR 

FOR DRAIN

  60 x 36 x 21 In. (1524 x 914 x 533mm)

54 Lbs. (24 Kg.)

487 Lbs. (221 Kg.)

52 Gal. (197 L.)

19 x 43 In. (483mm x 1092mm)

48-1/2 x 27 In. (1232mm x 686mm)

14 In. (356mm)

32 Lbs./Sq. Ft. (159 Kgs/Sq. m.)

23.8
44.5

GENERAL SPECIFICATIONS FOR 3571 BATHING POOL

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)

  72 x 36 x 21 In. (1829 x 914 x 533mm)

78 Lbs. (35 Kg.)

628 Lbs. (285 Kg.)

66 Gal. (250 L.)

19 x 55 In. (483mm x 1397mm)

60-1/2 x 27 In. (1537mm x 686mm)

14 In. (356mm)

35 Lbs./Sq. Ft. (170 Kgs/Sq. m.)

23.8
44.5

GENERAL SPECIFICATIONS FOR 3573 BATHING POOL

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)

ROUGH-IN REFERENCE
MODEL 3571002 GREEN TEA 5 x 36 BATH

ROUGH-IN REFERENCE
MODEL 3573002 GREEN TEA 6 x 36 BATH

Summary of Contents for DEEP SOAK 1640.305 Series

Page 1: ...INSTRUCTIONS Each bath arrives ready for installation however a drain overflow kit is required for each bath and it is not included The variety of installations for this bath may require framing proce...

Page 2: ...support structure per the local codes Note the bath deck must be self supporting 3 Cut bath deck to your specifications 4 Place the bath deck in position and trace the opening on the tub with a soft...

Page 3: ...m 2 51mm C L OF OVERFLOW LEVELING STRINGER NOT FOR SUPPORT 72 1829mm 36 914mm 11 1 2 292mm 14 3 4 375mm C L 9 229mm 19 483mm 2 51mm OUTLINE OF CUTOUT 70 5 x 34 5 1780 x 876mm 21 533mm 4 102mm INTEGRAL...

Page 4: ...wing 1 Defect or damages arising from shipping installation alterations accidents abuse misuse lack of proper maintenance and cleaning as directed in the Installation Instruction Manual and use of oth...

Page 5: ...100 years To ensure that your installation proceeds smoothly please read these instructions carefully before you begin Plumbers Putty or Caulking Phillips Screwdriver Channel Locks DEEP SOAK BATH DRAI...

Page 6: ...3 Apply sealant to threads of TAILPIECE 6 and thread into DRAIN TEE 3 Install OVERFLOW GASKET 4 to OVERFLOW TUBE ASSEMBLY 2 Adjust OVERFLOW GASKET 4 to couture of tub FIG 1 Loosen SLIP JOINT NUT SEAL...

Page 7: ...r below floor Fig 1 TYPICAL ABOVE FLOOR INSTALLATION 4 ABOVE FLOOR OUTLET INSTALLATION STANDARD DRAIN ABOVE FLOOR ROUGH BELOW FLOOR ROUGH TUB NOTE TUB IS SHOWN CUT AWAY FOR CLARITY OF INSTALLATION DO...

Page 8: ...to 6 00 p m EST IN CANADA 1 800 387 0369 TORONTO 1 905 306 1093 Weekdays 8 00 a m to 7 00 p m EST Product names listed herein are trademarks of American Standard Inc American Standard Inc 2007 754129...

Page 9: ...with LOCKNUT 6 Supplied with Fittings MOUNTING SURFACE 165 mm to 305 mm ADJ 6 1 2 TO 12 38 mm 1 1 2 MAX 32 mm 1 1 4 MAX 31 mm 1 3 16 DIA 76 mm 3 1 2 NPT 1 2 NPT 40 mm 1 5 8 DIA H C 29 mm 1 1 8 DIA 20...

Page 10: ...ly Check with local plumbing codes for backflow prevention requirements Install a backflow prevention device if required DIVERTER INSTALLATION FITTING MOUNTING SURFACE WATER INLET FROM TEE TUB OUTLET...

Page 11: ...from HANDLE ADAPTER 3 Loosen the adapter screw 4 Use a flat blade screw driver to remove SPRING CLIP 5 Lift STOP WASHER 6 turn 90 and replace Replace SPRING CLIP 5 Reinstall HANDLE ASSEMBLY 2 and tigh...

Page 12: ...ER 2 and HOSES for leaks Turn VALVES off If spout drips operate handles several times from OFF to ON position Do not force handles turn only 90 TEST INSTALLED FAUCET CAUTION The flow rate of this Tub...

Page 13: ...0070A TUBE TEE ASSEMBLY M970262 0070A SHANK KIT 030274 0070A SHANK MOUNTING KIT 911903 0070A RUBBER RING 028664 YYY0A HAND SHOWER HOLDER 1660207 XXX HAND SHOWER 918319 0070A SCREW M918464 0070A SPINDL...

Reviews: