5
ADJUSTING DOOR PANEL
5a.
Close Door Panel [
9
] and observe if there are any gaps between the Door Panel [
9
] and Fixed Panel B [
11
]
or if the door is high or low at any location (ref. illustration). Also both Fixed Door Panels A or B can be
moved in or out from the Wall Post [
1
] (note: will need to loosen Adjustment Fixtures [
15
] to do so to aid
in adjusting the Door Panel [
9
]).
5b.
If Door Panel [9] is lower when closed against Fixed Panel B [
11
], then slide Gasket [
27
] under Fixed
Panel A [
10
] to slightly raise Door Panel [9].
5c.
Trim Gasket [
27
] with Utility Knife [
H
].
5d.
Further adjustment of any gap between Door Panel [
9
] and Fixed Panel B [
11
] can be made my pushing
either Magnetic Seal [
7
] or [
8
] in or out.
5e.
Once all adjustments have been made, verify that the Door Panel [
9
] closes smoothly and correctly with
no gaps. (ref. illustration).
• In this step, you’ll need following part: [27]
• In this step, you’ll need the following tool: H
[
8
]
[
27
]
[
9
]
[
9
]
[
9
]
[
11
]
[
9
]
[
11
]
[
11
]
[
7
]
[
7
]
[
8
]
Incorrect Fit
Shower
Base
Threshold
Shower
Base
Threshold
Correct Fit
Incorrect Fit
Incorrect Fit
Correct Fit
H
[
10
]
[
10
]
[
9
]
5a
5e
5b
5a
5b
5d
5c
5e
[
8
]
[
7
]