background image

INSTALLATION INSTRUCTIONS

751753-100 Rev.J

© American Standard Inc. 2003
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.

HIGH GLOSS ACRYLIC
SHOWN LESS ALL FITTINGS

ELLISSE OVAL™ 

WHIRLPOOL/BATHING POOL

2709.XXXW SERIES

FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.

GENERAL SPECIFICATIONS FOR 2709 WHIRLPOOL

69-1/4 x 38-1/2 x 19-3/4 In.(1759 x 978 x 502mm)

107 Lbs. (49 Kg.)

640 Lbs. (291 Kg.)

64 Gal. (243 L)
53 Gal. (201 L)

45 x 23 In. (1143 x 584mm)
63 x 32 In. (1600 x 813mm)

13 In. (330mm)

35 Lbs./Sq.Ft. (166 Kgs./Sq.m)

25.6
49.4

WHIRLPOOL ELECTRICAL SPECIFICATIONS

2.1 HP, 14.4 AMPS, 120V.
2.1 HP, 15.6 AMPS, 120V.

SYSTEM I PUMP
SYSTEM II PUMP

SAFETY HEATER ________________________________12 AMPS, 120V.

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT3)

1759 mm

(69-1/4)

ROUGH 
FLOOR

1-1/2 O.D.

TAILPIECE

OUTLINE OF

CUTOUT

240 mm
(9-7/16)

978 mm
(38-1/2)

464mm

(18-1/4)

INTEGRAL
FEET
SUPPORT

86mm

(3-3/8)

38mm

(1-1/2)

489mm

(19-1/4)

76mm

(3)

C

L OF DRAIN

OUTLET

502mm

(19-3/4 )

1-1/2 N.P.T.M.

THREADS

35mm

(1-3/8)

305mm(12) X 229 mm(9)
CUTOUT IN FLOOR FOR DRAIN

98mm
(3-7/8)

PROVIDE ACCESS

TO PUMP FOR

SERVICING ON ALL

INSTALLATIONS

ON/OFF

SWITCH

PUMP

SEE FTTG.SPECS

FOR DIMENSION

CL OF SUPPLIES

C/L OF
SPOUT

C/L OF

VALVES

C/L OF

SHOWER ARM

1651-1981mm

(65-78)

OPTIONAL

102mm
(4)

 

305mm

(12)

T H A N K     Y O U . . .

for selecting an American Standard bath. Your new 
bath is shipped to you after careful inspection. The 
whirlpool version is completely assembled with pump, 
motor, and system piping. All you need to finish the 
installation are your selected fittings and electrical 
connections for a whirlpool.

To insure maximum performance and pleasure from 
this product, please follow the instructions and 
cautions. 

GENERAL INSTALLATION INFORMATION

Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor 
immediately.

After inspection and during installation, protect the bath from construction damage. After installation, and before 
enclosing with wallboard, tile, etc., water test the unit and check for leaks.

Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect 
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, 
motor, or piping system.

Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and 
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead 
(required for recess installations).

Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.  

WARNING! Do not lift whirlpool by the piping harness at any time.

List of Optional Components (not included):
•  Safe-T-Heater 9075.120*

see your American Standard Distributor

List of Required Components (not included):
•  Drain 1583.470*
•  Bath Filler* 

* see your American Standard Distributor

List of Required Tools and Supplies:

Tools
•  Level
•  Tape Measure
•  Pipe Wrench
•  Slip Joint Pliers
•  Screw Driver
•  Standard
      Woodworking Tools
•  Personal Safety
      Equipment
•  Caulking Gun

Supplies
•  Nails
•  Putty
•  Caulking (waterproof)
•  1 x 3 or 2 x 2
      Stringers
•  Drop Cloth
•  20 amp GFCI
      Outlet
•  Cement, Plaster,
      Grout

SAFE-T-HEATER

REMOVABLE BLANK

Summary of Contents for Ellisse Oval Bathtub 2709.XXXW

Page 1: ...and system piping All you need to finish the installation are your selected fittings and electrical connections for a whirlpool To insure maximum performance and pleasure from this product please follow the instructions and cautions GENERAL INSTALLATION INFORMATION Carefully uncrate and inspect your new bath for any shipping damage If such damage is found report it to your vendor immediately After...

Page 2: ...INSURE ROUGH DIMENSIONS ARE PROPER PLUMB AND SQUARE FOR WHIRLPOOLS PROVISION MUST BE MADE IN ALL INSTALLATIONS FOR AN ACCESS OPENING FOR SERVICING PUMP AND CONTROLS THE FOLLOWING PROCEDURE MUST BE USED FOR ALL INSTALLATIONS STRINGER OR PIER HEIGHT SHOULD BE AS INDICATED THE SUMP OF THE BATH IS SUPPORTED BY INTEGRAL FEET AND NO ADDITIONAL SUMP SUPPORT IS REQUIRED ONCE THE BATH IS IN PLACE THE FEET ...

Page 3: ...IC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounded 3 Install to permit access for servicing 4 All building materials and wiring should be routed away from the pump body and heater if equipped 2 1 HORSEPOWER MODELS The whirlpool should be installed on a 120 vac 20 amp dedicate...

Page 4: ...en popsicle stick or tongue depressor Do not use wire brushes or any other metal implement on bath surface Post installation clean up generally can be completed using warm water and liquid dishwashing detergent Stubborn dirt or stains may be removed using granular Spic and Span mixed with water Painter s naphtha can be used to remove excess adhesives and or wet oil base paint HARSH CHEMICALS SHOUL...

Reviews: