background image

DRAIN CONNECTION AND SYSTEM TEST

POST INSTALLATION CLEAN-UP

Using recommended drain assembly, connect whirlpool drain to waste line in accordance with the drain  

assembly instructions.Tighten all drain joints securely. Check the pump couplings and make sure they are  

hand-tight. Clean the whirlpool and fill withwater to a point 2"" above the top of the highest jet. Recheck the 

pump couplings and make certain that they are not leaking. (Although the pump couplings are factory tightened 

and inspected, some loosening may have occurred during transit.) Make sure the whirlpool is connected to  

the electrical supply and turn the whirlpool on. Check for leaks around all piping connections while the whirlpool 

is running.

Remove all construction debris from bath. Tile grout can be removed with a wooden popsicle stick or tongue 

depressor. Do not use wire brushes or any other metal implement on bath surface. Post installation clean-up 

generally can be completed using warm water and liquid dishwashing detergent. Stubborn dirt or stains may 

be removed using granular Spic and Span

®

 mixed with water. Painter’s naphtha can be used to remove excess 

adhesives and/or wet oil-base paint.

AFTERCARE AND CLEANING

The high gloss surface is resistant to impact and chemicals and will retain its lasting luster with proper care  

and maintenance.
 Always fill the tub with temperate water. Excessively hot water may cause surface damage.
Clean after use with a mild liquid household detergent cleaner. Do not use Lestoil

®

, Lysol

®

 Disinfectant (spray or 

concentrate), or Lysol Basin, Tub and Tile Cleaner, Windex, Mr. Clean

®

, Dow

®

 Disinfectant Bathroom Cleaner, or 

cleaning products in aerosol cans.For occasional, more concentrated cleaning efforts Lysol Non-Abrasive Bath-
room Cleaner works extremely well.

HARSH CHEMICALS SHOULD NEVER BE USED ON ACRYLIC SURFACES. 

Do not use wire brushes, knives or sharp objects to remove stains, cigarette tar deposits,or other  

surface blemishes.
Abrasive cleaners or powders must not be used, since they will dull the surface. If the glossy surface looses 

its sheen, dulled areas can be restored by rubbing with a white “automotive type” polishing compound and 

waxing with a “liquid wax.”

Do not wax areas where you walk or stand.

Do not allow nail polish remover, acetone, dry cleaning fluid, paint remover or other solvents to come into 

contact with the surface.
Clean the surrounding surface immediately after using caustic drain cleaners.
Burning cigarettes will damage the surface.

Should damage to the fixture occur, repairs can be made quickly and easily. Your distributor or builder can 

provide details.
Do not permit drain cleaner to enter the circulation system.

CIRCULATION SYSTEM CLEANING-PURGING PROCEDURES 

STEP 1.

  Once every month purge and clean the circulating system. Fill whirlpool with warm water and  

add two teaspoons of dishwasher detergent and one-half cup of house hold bleach.

STEP 2.

 Activate whirlpool system in accordance with operating instructions or two minutes.

STEP 3.

 Drain and refill whirlpool with cool water and circulate for additional five minutes.

STEP 4.

 Drain whirlpool completely.

Summary of Contents for Mainstream 2948LC-LHO.020

Page 1: ...ars We believe that while every home should appreciate in value we never forget the sentimental value that grows from enjoying life in the heart of home your kitchen and bath That s why we love your s...

Page 2: ...e Inspect the product and report any damages or missing parts immediately to customer care by calling 800 442 1902 Mainstream Whirlpool dimensions are nominal and meant for a standard 60 1524 mm alcov...

Page 3: ...the bathtub Never drop or insert any object into any opening Use this unit only for its intended use as described in this manual Do not use any attachments not recommended by American Standard The uni...

Page 4: ...tc the bath must be filled with water and operated to check for leaks that may have resulted from shipping damage or mishandling Do not make modifications to the whirlpool system or remove pump from f...

Page 5: ...for Field Installation Gallon to Overflow Whirlpool Operating Volume 2949LC 020 L 1524 mm 60 W 832 mm 32 3 4 H 502 mm 19 3 4 A 438 mm 17 1 4 B 216 mm 28 1 2 C 464 mm 18 1 4 1485 mm 58 1 2 X 794 mm 31...

Page 6: ...Mainstream 60x32 8 Jet Right Hand Outlet Shown 2948LC LHO 020 Mainstream 60x32 8 Jet Left Hand Outlet 9 229mm PUMP APRON IS PRIMARY ACCESS OPENING FOR MODELS RHO LHO ONLY C L OF DRAIN OUTLET CUT OUT...

Page 7: ...erflow of the bath extends below the bottom of the bath Note that this requires a cutout in the floor The floor structure beneath the bath must be able to support a total weight of bath water and bath...

Page 8: ...bath TYPICAL PIER TYPE INSTALLATION AS DESIRED F CUTOUT AS DESIRED G CUTOUT C 24 610 mm 12 305 mm MOUNTING SURFACE WATERPROOF SEALANT BATH TYPICAL RECESS INSTALLATION 24 610 mm 12 305 mm C E D W LEVEL...

Page 9: ...outed away from the pump body and heater if equipped GFCI CIRCUIT REQUIREMENTS The whirlpool should be installed on a 120 vac 15 amp dedicated GFCI circuit The circuit should be hard wired from the el...

Page 10: ...ress and whirlpool will start 4c Stop Whirlpool Depress and release button and whirlpool will stop 4d Air Volume Control Adjustments Water turbulence is determined by the amount of air mixed with the...

Page 11: ...household detergent cleaner Do not use Lestoil Lysol Disinfectant spray or concentrate or Lysol Basin Tub and Tile Cleaner Windex Mr Clean Dow Disinfectant Bathroom Cleaner or cleaning products in aer...

Page 12: ...e year after its initial purchase confirms that it is defective in materials or workmanship American Standard will repair or at its option exchange the product for a similar model This warranty applie...

Page 13: ...ericanstandard 755967 100 2 21 Great Tub 03 13 2018 06 52 29 CDT American Standard Bathtubs Saver 60 Inch by 34 Inch Integral Apron Bathtub Left Hand Drain Love the tub It is very roomy and would defi...