IMPORTANT SAFETY INSTRUCTIONS

INSTRUCTIONS PERTAINING TO A RISK OF FIRE, ELECTRIC SHOCK OR INJURY TO PERSONS
READ AND FOLLOW ALL INSTRUCTIONS!

!

 WARNING: 

Risk of personal injury.

 Do not permit children to use this unit without adult supervision.

!

 WARNING:

 

Risk of personal injury.

 Do not operate this unit without the guard over the suction fitting.

!

 WARNING:  

Risk of electric shock. 

Do not permit electrical appliances (hair dryer, telephone, radio, etc.) 

within 60 inches (1524mm) of this unit.

!

 WARNING: 

 

Risk of hyperthermia and possible drowning.

 People using medications and/or having ad-

verse medical history should consult a physician before using this product.

!

 WARNING:  

Risk of personal injury.

 Do not overfill unit before entering. Entering tub when filled more than 

2/3 can cause overflow and slippery conditions. Exercise caution when entering and exiting.

!

 WARNING:  

No Food or Alcoholic Beverages. 

Use of your bathtub immediately after meals is not 

recommended. Avoid alcohol consumption before or during bathing. Alcoholic beverages can 

cause drowsiness or hyperthermia resulting in loss of consciousness or even drowning.

!

 WARNING: 

 

Pregnancy.

 If you are or think you may be pregnant, consult your physician before using  

the bathtub.

Never drop or insert any object into any opening.

Use this unit only for its intended use as described in this manual. Do not use any attachments not  

recommended by American Standard.

The unit must be connected only to a supply circuit that is properly protected by a ground-fault  

circuit-interrupter (GFCI). Such a GFCI should be provided by the installer and should be tested on a routine 

basis. To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power 

should be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power 

to the bathtub without the test button being pushed, a ground current is flowing, indicating the possibility of an 

electric shock. Do not use this hydromassage bathtub. Disconnect the hydromassage bathtub and have the 

problem corrected by a licensed electrician before using.

A pressure wire connector is provided on the exterior of the motor unit to permit connection of a no. 8 AWG 

solid copper bonding conductor between this unit and all other electrical equipment and exposed metal in the 

vicinity, as needed to comply with local requirements. To reduce the risk of an electric shock, connect this con-

nector to the grounding terminal of your electric service or supply panel with a conductor equivalent in size to 

the circuit conductors supplying this unit.

SAVE THESE INSTRUCTIONS

Summary of Contents for Mainstream 2948LC-LHO.020

Page 1: ...ars We believe that while every home should appreciate in value we never forget the sentimental value that grows from enjoying life in the heart of home your kitchen and bath That s why we love your s...

Page 2: ...e Inspect the product and report any damages or missing parts immediately to customer care by calling 800 442 1902 Mainstream Whirlpool dimensions are nominal and meant for a standard 60 1524 mm alcov...

Page 3: ...the bathtub Never drop or insert any object into any opening Use this unit only for its intended use as described in this manual Do not use any attachments not recommended by American Standard The uni...

Page 4: ...tc the bath must be filled with water and operated to check for leaks that may have resulted from shipping damage or mishandling Do not make modifications to the whirlpool system or remove pump from f...

Page 5: ...for Field Installation Gallon to Overflow Whirlpool Operating Volume 2949LC 020 L 1524 mm 60 W 832 mm 32 3 4 H 502 mm 19 3 4 A 438 mm 17 1 4 B 216 mm 28 1 2 C 464 mm 18 1 4 1485 mm 58 1 2 X 794 mm 31...

Page 6: ...Mainstream 60x32 8 Jet Right Hand Outlet Shown 2948LC LHO 020 Mainstream 60x32 8 Jet Left Hand Outlet 9 229mm PUMP APRON IS PRIMARY ACCESS OPENING FOR MODELS RHO LHO ONLY C L OF DRAIN OUTLET CUT OUT...

Page 7: ...erflow of the bath extends below the bottom of the bath Note that this requires a cutout in the floor The floor structure beneath the bath must be able to support a total weight of bath water and bath...

Page 8: ...bath TYPICAL PIER TYPE INSTALLATION AS DESIRED F CUTOUT AS DESIRED G CUTOUT C 24 610 mm 12 305 mm MOUNTING SURFACE WATERPROOF SEALANT BATH TYPICAL RECESS INSTALLATION 24 610 mm 12 305 mm C E D W LEVEL...

Page 9: ...outed away from the pump body and heater if equipped GFCI CIRCUIT REQUIREMENTS The whirlpool should be installed on a 120 vac 15 amp dedicated GFCI circuit The circuit should be hard wired from the el...

Page 10: ...ress and whirlpool will start 4c Stop Whirlpool Depress and release button and whirlpool will stop 4d Air Volume Control Adjustments Water turbulence is determined by the amount of air mixed with the...

Page 11: ...household detergent cleaner Do not use Lestoil Lysol Disinfectant spray or concentrate or Lysol Basin Tub and Tile Cleaner Windex Mr Clean Dow Disinfectant Bathroom Cleaner or cleaning products in aer...

Page 12: ...e year after its initial purchase confirms that it is defective in materials or workmanship American Standard will repair or at its option exchange the product for a similar model This warranty applie...

Page 13: ...ericanstandard 755967 100 2 21 Great Tub 03 13 2018 06 52 29 CDT American Standard Bathtubs Saver 60 Inch by 34 Inch Integral Apron Bathtub Left Hand Drain Love the tub It is very roomy and would defi...