INSTALL MIRROR/MEDICINE CABINET
M968408D
Install MIRROR/MEDICINE CABINET into finished opening in wall. Check for level and that cabinet frame fits
flush against finished wall. Shim as required to make level. (Figure A)
Drill two 1/8" dia. pilot holes into top and bottom of cabinet. Secure cabinet to framing with wood screws. (Figure B)
!
INSTALL MOUNTING PLATES
To use TEMPLATES (A & B),
to locate the center of each MOUNTING PLATE (1), cut the template out cutting on the dotted lines.
Starting at lower left corner of cabinet frame, locate the template as illustrated. Tape into place and mark the three centers of the
MOUNTING PLATE (1). Use TEMPLATE (A) for corners 1 & 3 and TEMPLATE (B) for corners 2 & 4 marking the MOUNTING PLATE (1)
locations and mounting holes. Check with a level that the center to center measurements are level.
To use DIMENSIONS,
to locate the center of each MOUNTING PLATE (1) start at the lower left corner of cabinet frame. Measure as
indicated to locate the center of each MOUNTING PLATE (1). Mark the centers for the left side MOUNTING PLATE (1) and use the same
measurements to locate the centers of the right side. Check with a level that the center to center measurements are level.
For best installation results it is recommended to secure MOUNTING PLATES (1) to reinforcements studs. No Anchors are needed. Drill
small pilot holes for SCREWS (3).
For installations on drywall without reinforcement studs,
use DRYWALL ANCHORS (2) and SCREWS (3) for securing
MOUNTING PLATE (1) to wall. Place #2 Phillips screwdriver or cordless screwdriver into recess of anchor. Press into drywall while turning
the anchor clockwise until it is seated flush with the wall. Place MOUNTING PLATE (1) over DRYWALL ANCHOR (2) and insert SCREWS (3)
with #2 Phillips screwdriver. See FIGURE B below. Secure MOUNTING PLATE (1) to wall with SCREWS (3).
NOTE; For best installation results use:
• No Anchors, Screws (3) directly secured to
reinforcement studs
• TILE ANCHORS (4) for tile or plaster walls
• DRYWALL ANCHORS (2) for dry wall
1
2
FINISHED
WALL
2
4
3
CENTER LINE
1
PILOT HOLES
Figure A
Figure B
Figure B
For installations on tiled walls without reinforcement studs,
If TILE ANCHORS (4) and SCREWS (3) are used for securing MOUNTING
PLATE (5), then drill two 1/4" diameter holes a minimum of 1-1/4" deep. Insert the two TILE ANCHORS (4) flush with face of the
finished wall. Secure MOUNTING PLATE (1) to wall with SCREWS (3).
Note: Cabinet can be installed either right hand or left hand by rotating cabinet180 degrees.
Note: Refer to Figure A for use of
TEMPLATES (A & B)
or
DIMENSIONS
to locate the four MOUNTING PLATES (1).
A
LOWER LEFT
CORNER
OF CABINET
1
1-15/16"
19-3/8"
25-1/2"
LEVEL
1-15/16"
1-3/32"
1-3/32"
Figure A
1
2
4
3