background image

Page 10

Pub. No. 32-5034-02

Warranty Information

I

t’s always a good idea to keep records which will save you time

and money. If it’s necessary to have your FURNACE repaired,
the service man will want to know if your unit is still under
Warranty. To save time, take a few minutes to record the
following information here:
Model Number:_____________________________________
Serial Number: _____________________________________
Date of Purchase:___________________________________

Service Information

Call your installing dealer if the unit is inoperative. Before
you call, always check the following to be sure service is
really required:

a. Be sure the main switch that supplies power to the unit is
in the “ON” position.

b. Replace any burned-out fuses or reset circuit breakers.

c. Be sure the thermostat is properly set.

Extended warranties are available from the manufacturer through your dealer.  The limited warranty is backed by the
manufacturer and any representations made about extending the limited warranty would be backed by the manufacturer if and
only if an extended warranty agreement was received 

from the manufacturer

.

Limited Warranty

High Efficiency Induced Draft Gas Furnace

UE, DE, UD-R, DD-R, UD-RV, DD-RV,

UD-C, DD-C, CUB and CDB

Models Less Than 20 Tons for Residential Use*

(Parts Only)

This limited warranty is extended by American Standard Inc., to the original purchaser and to any succeeding
owner of the real property to which the Gas Furnace is originally affixed, and applies to products purchased and
retained for use within the U.S.A. and Canada.

If any part of your Gas Furnace fails because of a manufacturing defect within five years from the date of the
original purchase, Warrantor will furnish without charge the required replacement part. Any local transportation,
related service labor, air filters, and diagnosis calls, are not included.

In addition, if the steel heat exchanger fails because of a manufacturing defect within the sixth through twentieth
year from the date of original purchase, Warrantor will furnish without charge a replacement heat exchanger. Any
local transportation, related service labor, air filters, and diagnosis calls, are not included.

This limited warranty does not cover failure of your gas furnace if it is damaged while in your possession, failure
attributable or caused by unreasonable use of the gas furnace and/or failure to properly maintain the gas furnace
as set forth in the Use and Care manual.

This limited warranty applies to product installed on or after 10/1/2001 where product is manufactured after
1/1/2000. This limited warranty is not retroactive to any installations prior to 10/1/2001 or on product produced
prior to 2000.

THE LIMITED WARRANTY AND LIABILITY SET FORTH HEREIN ARE IN LIEU OF ALL OTHER
WARRANTIES AND LIABILITIES, WHETHER IN CONTRACT OR IN NEGLIGENCE, EXPRESS OR
IMPLIED, IN LAW OR IN FACT, INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR PARTICULAR USE, AND IN NO EVENT SHALL WARRANTOR BE LIABLE FOR ANY
INCIDENTAL OR CONSEQUENTIAL DAMAGES.

Some states do not allow limitations on how long an implied limited warranty lasts or do not allow the exclusion
or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
This limited warranty gives you specific legal rights, and you may also have other rights which vary from state to
state.

Parts will be provided by our factory organization through an authorized service organization in your area listed
in the yellow pages. If you wish further help or information concerning this limited warranty, contact:

American Standard Inc.
Troup Highway
Tyler, TX 75711-9010
Attention: Manager, After Sales Support

GW-615-4001

* This limited warranty is for residential usage of this equipment and not applicable when this equipment is used
for a commercial application. A commercial use is any application where the end purchaser uses the product for
other than personal, family or household purposes.

Summary of Contents for Noncondensing Gas Furnaces

Page 1: ...O RECOGNIZE THESE HAZARDS AND PROCEED SAFELY American Standard Inc 2001 WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage persona...

Page 2: ...ll restrict the flow of fresh air The combustion air for your furnace must be fresh uncon taminatedair Paints varnishes laundrybleaches deter gents many household cleaners water softening salts adhesi...

Page 3: ...d filter rack on the upflow models all cleaning or replacing of filters is quick and easy Clean filters guarantee optimum performance of your system Replacing your filter When replacing your furnace f...

Page 4: ...ntal Furnace Filters The Upflow Horizontal furnace when installed horizon tally requires a horizontal filter kit The filters may be located remote to the furnace or in the return air duct near the fur...

Page 5: ...21 and 24 1 2 wide furnace cabinets DOWNFLOW FILTER TABLE REQUIRED FILTERS DOWNFLOW CABINET WIDTH FILTER QUANTITY SIZE 14 1 2 2 14 X 20 X 1 17 1 2 2 16 X 20 X 1 21 2 16 X 20 X 1 24 1 2 2 16 X 20 X 1...

Page 6: ...tic and will recycle If your unit still does not operate call for servicer 4 Burner does not ignite 4 Call servicer 5 Main gas line turned off 5 Have gas company check 6 Blower door removed or ajar 6...

Page 7: ...nersmustbecleanedannuallyusingbrushes and vacuum cleaner Turn off gas and electric power supply To clean burners remove top burner bracket and lift burner from orifice NOTE Be careful not to break ign...

Page 8: ...after the furnace is in stalled the area around the furnace must be inspected to ensure it is free and clear of insulation If this furnace is installedinanatticorotherinsulatedspaceitmustbekept free...

Page 9: ...ink behind gas valve In case of main gas valve malfunction and consequent overheating link will open and close off flow of all gas See instruction label on front panel of heat exchanger Lighting instr...

Page 10: ...hanger fails because of a manufacturing defect within the sixth through twentieth year from the date of original purchase Warrantor will furnish without charge a replacement heat exchanger Any local t...

Page 11: ...OSH approved dust mist respirator Avoid contact with the skin or eyes Wear long sleeved loose fitting clothing gloves and eye protection Wash clothes separately from other clothing rinse washer thorou...

Page 12: ...02 American Standard Inc 6200 Troup Highway Tyler TX 75711 9010 Since the manufacturer has a policy of continuous product and product data improvement it reserves the right to change design and specif...

Page 13: ...O RECOGNIZE THESE HAZARDS AND PROCEED SAFELY American Standard Inc 2001 WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage persona...

Page 14: ...ll restrict the flow of fresh air The combustion air for your furnace must be fresh uncon taminatedair Paints varnishes laundrybleaches deter gents many household cleaners water softening salts adhesi...

Page 15: ...d filter rack on the upflow models all cleaning or replacing of filters is quick and easy Clean filters guarantee optimum performance of your system Replacing your filter When replacing your furnace f...

Page 16: ...ntal Furnace Filters The Upflow Horizontal furnace when installed horizon tally requires a horizontal filter kit The filters may be located remote to the furnace or in the return air duct near the fur...

Page 17: ...21 and 24 1 2 wide furnace cabinets DOWNFLOW FILTER TABLE REQUIRED FILTERS DOWNFLOW CABINET WIDTH FILTER QUANTITY SIZE 14 1 2 2 14 X 20 X 1 17 1 2 2 16 X 20 X 1 21 2 16 X 20 X 1 24 1 2 2 16 X 20 X 1...

Page 18: ...tic and will recycle If your unit still does not operate call for servicer 4 Burner does not ignite 4 Call servicer 5 Main gas line turned off 5 Have gas company check 6 Blower door removed or ajar 6...

Page 19: ...nersmustbecleanedannuallyusingbrushes and vacuum cleaner Turn off gas and electric power supply To clean burners remove top burner bracket and lift burner from orifice NOTE Be careful not to break ign...

Page 20: ...after the furnace is in stalled the area around the furnace must be inspected to ensure it is free and clear of insulation If this furnace is installedinanatticorotherinsulatedspaceitmustbekept free...

Page 21: ...ink behind gas valve In case of main gas valve malfunction and consequent overheating link will open and close off flow of all gas See instruction label on front panel of heat exchanger Lighting instr...

Page 22: ...hanger fails because of a manufacturing defect within the sixth through twentieth year from the date of original purchase Warrantor will furnish without charge a replacement heat exchanger Any local t...

Page 23: ...OSH approved dust mist respirator Avoid contact with the skin or eyes Wear long sleeved loose fitting clothing gloves and eye protection Wash clothes separately from other clothing rinse washer thorou...

Page 24: ...02 American Standard Inc 6200 Troup Highway Tyler TX 75711 9010 Since the manufacturer has a policy of continuous product and product data improvement it reserves the right to change design and specif...