Pub. No. 32-5034-02

Page 3

Filter maintenance reduces energy use.

WARNING:

 

Disconnect power to the

unit before removing the blower door.  Failure to
follow this warning could result in property damage,

personal injury or death.

A clean filter saves money.

When the furnace circulates and filters the air in your
home, dust and dirt particles build up on the filter.
Excessive accumulation can block the airflow, forcing
the unit to work harder to maintain desired tempera-
tures.

And the harder your unit has to work, the more energy
it uses. So you pay more any time your system is run-
ning with a dirty filter.

CAUTION: Never operate your unit for either
heating or cooling with filters removed.

Help ensure top efficiency by cleaning the filter once a
month.  If you have an upflow furnace, you can wash or

change the filter once a month. Clean it twice a month
during seasons when the unit runs more often.

Your furnace came from the factory with a cleanable
filter. You can clean the filter with a vacuum, OR you
can wash it with a household detergent.  Good quality,
high velocity filters may be used for replacements in
upflow furnaces.

With the new patented filter rack on the upflow models,
all cleaning or replacing of filters is quick and easy.
Clean filters guarantee optimum performance of your
system.

Replacing your filter.

When replacing your furnace filters, use a high velocity
type filter. On upflow furnaces, standard size 1" thick
high velocity filters will fit into the patented filter rack
which will automatically adjust in width to fit. Filters
are available from your dealer.

How to remove your filter.

WARNING:

 Disconnect power to the

unit before removing the blower door.  Failure to
follow this warning could result in property damage,
personal injury or death.

The upflow furnace blower door has a hinge at the
bottom which allows the door to tilt forward for filter
servicing or replacement without the door being re-
moved.  The furnace filter in the bottom or side configu-
ration can be removed by simply turning the two latches
on the blower door 1/4 turn and tilting the door forward.

The blower door may be removed if necessary by tilting the
door outward 2 to 3 inches, then pulling up.  The door will
slide out of the hinge for removal.  For replacement, simply
insert the blower door bottom into the space between the
furnace base front and the hinge, then tilt inward and
latch.

Blower Door Hinge and Bottom Filter Rack Installation

Typical Upflow Right Side Return Filter Installation

Summary of Contents for Noncondensing Gas Furnaces

Page 1: ...O RECOGNIZE THESE HAZARDS AND PROCEED SAFELY American Standard Inc 2001 WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage persona...

Page 2: ...ll restrict the flow of fresh air The combustion air for your furnace must be fresh uncon taminatedair Paints varnishes laundrybleaches deter gents many household cleaners water softening salts adhesi...

Page 3: ...d filter rack on the upflow models all cleaning or replacing of filters is quick and easy Clean filters guarantee optimum performance of your system Replacing your filter When replacing your furnace f...

Page 4: ...ntal Furnace Filters The Upflow Horizontal furnace when installed horizon tally requires a horizontal filter kit The filters may be located remote to the furnace or in the return air duct near the fur...

Page 5: ...21 and 24 1 2 wide furnace cabinets DOWNFLOW FILTER TABLE REQUIRED FILTERS DOWNFLOW CABINET WIDTH FILTER QUANTITY SIZE 14 1 2 2 14 X 20 X 1 17 1 2 2 16 X 20 X 1 21 2 16 X 20 X 1 24 1 2 2 16 X 20 X 1...

Page 6: ...tic and will recycle If your unit still does not operate call for servicer 4 Burner does not ignite 4 Call servicer 5 Main gas line turned off 5 Have gas company check 6 Blower door removed or ajar 6...

Page 7: ...nersmustbecleanedannuallyusingbrushes and vacuum cleaner Turn off gas and electric power supply To clean burners remove top burner bracket and lift burner from orifice NOTE Be careful not to break ign...

Page 8: ...after the furnace is in stalled the area around the furnace must be inspected to ensure it is free and clear of insulation If this furnace is installedinanatticorotherinsulatedspaceitmustbekept free...

Page 9: ...ink behind gas valve In case of main gas valve malfunction and consequent overheating link will open and close off flow of all gas See instruction label on front panel of heat exchanger Lighting instr...

Page 10: ...hanger fails because of a manufacturing defect within the sixth through twentieth year from the date of original purchase Warrantor will furnish without charge a replacement heat exchanger Any local t...

Page 11: ...OSH approved dust mist respirator Avoid contact with the skin or eyes Wear long sleeved loose fitting clothing gloves and eye protection Wash clothes separately from other clothing rinse washer thorou...

Page 12: ...02 American Standard Inc 6200 Troup Highway Tyler TX 75711 9010 Since the manufacturer has a policy of continuous product and product data improvement it reserves the right to change design and specif...

Page 13: ...O RECOGNIZE THESE HAZARDS AND PROCEED SAFELY American Standard Inc 2001 WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage persona...

Page 14: ...ll restrict the flow of fresh air The combustion air for your furnace must be fresh uncon taminatedair Paints varnishes laundrybleaches deter gents many household cleaners water softening salts adhesi...

Page 15: ...d filter rack on the upflow models all cleaning or replacing of filters is quick and easy Clean filters guarantee optimum performance of your system Replacing your filter When replacing your furnace f...

Page 16: ...ntal Furnace Filters The Upflow Horizontal furnace when installed horizon tally requires a horizontal filter kit The filters may be located remote to the furnace or in the return air duct near the fur...

Page 17: ...21 and 24 1 2 wide furnace cabinets DOWNFLOW FILTER TABLE REQUIRED FILTERS DOWNFLOW CABINET WIDTH FILTER QUANTITY SIZE 14 1 2 2 14 X 20 X 1 17 1 2 2 16 X 20 X 1 21 2 16 X 20 X 1 24 1 2 2 16 X 20 X 1...

Page 18: ...tic and will recycle If your unit still does not operate call for servicer 4 Burner does not ignite 4 Call servicer 5 Main gas line turned off 5 Have gas company check 6 Blower door removed or ajar 6...

Page 19: ...nersmustbecleanedannuallyusingbrushes and vacuum cleaner Turn off gas and electric power supply To clean burners remove top burner bracket and lift burner from orifice NOTE Be careful not to break ign...

Page 20: ...after the furnace is in stalled the area around the furnace must be inspected to ensure it is free and clear of insulation If this furnace is installedinanatticorotherinsulatedspaceitmustbekept free...

Page 21: ...ink behind gas valve In case of main gas valve malfunction and consequent overheating link will open and close off flow of all gas See instruction label on front panel of heat exchanger Lighting instr...

Page 22: ...hanger fails because of a manufacturing defect within the sixth through twentieth year from the date of original purchase Warrantor will furnish without charge a replacement heat exchanger Any local t...

Page 23: ...OSH approved dust mist respirator Avoid contact with the skin or eyes Wear long sleeved loose fitting clothing gloves and eye protection Wash clothes separately from other clothing rinse washer thorou...

Page 24: ...02 American Standard Inc 6200 Troup Highway Tyler TX 75711 9010 Since the manufacturer has a policy of continuous product and product data improvement it reserves the right to change design and specif...

Reviews: