  MAINTENANCE

A

      

HAND WASH SENSOR OPERATION; 

Fig. 7

REMOVE PROTECTIVE FILM FROM SENSOR EYE WHEN  

INSTALLATION IS COMPLETE.
When the Sensor detects a user, the water immediately starts 

to flow. Water flow will stop 1.5 seconds after user is out of 

sensor range. This Comfort delay allows the user to comfort-

ably move their hands without the water turning off. 
As a precaution, a Safety Timer will turn off the water after the 

sensor has been blocked for 59 seconds. The water will stay 

off until the  

blockage is removed from the detection zone.  
The Comfort and Safety time settings can be adjusted using 

the  
Optional Remote Control (605XRCT).

B

      

REPLACE BATTERY; Fig. 8, 9

1.  Remove 3 COVER SCREWS (1) and lift COVER (15) off.
2.  Disconnect SENSOR CABLES (6) and (7) from the  

BATTERY and SOLENOID VALVE. 

(Fig. 9)

3.   Push BATTERY (17) forward and Pull it out. (Fig. 8)
4.   
Replace the new battery with the same placement.  

(Insert terminal side first)

C

     

CHANGE SENSOR RANGE;  

Fig. 8, 9

1.  Remove 3 COVER SCREWS (1).
2.  Remove the COVER (15).
3.  Disconnect the BLACK POWER SUPPLY CONNECTOR (7) 

and reconnect. 

Fig. 9.

4.  While the SENSOR CONTROL LED (9) is blinking slowly,  

place your hand 1 - 2 in. (25.4-50.8mm) in front of the sensor.

5.  When the LED stops blinking and stays “ON”, move your hand 

to the desired position and hold in place until the LED begins 

to blink again. 

6.  Once the SENSOR CONTROL LED (9) begins to blink 

again,  

remove your hand from the detection zone. When the flashing 

stops, the detection distance is set.

7.  Reassemble the COVER (15) and secure it  with COVER 

SCREWS 

(1).

15

16

2

1

4

9

14

7

Fig. 8

Fig. 9

6

12

17

Fig. 4

DETECTION

ZONE

PROTECTIVE FILM

IMPORTANT: Do not

use sealent on threads

1

2

3

COLD

HOT

(3) INLINE

FILTER

Fig. 6

5

4

Fig. 5

1

9

8

7

5

3

1

Fig. 7

Summary of Contents for Paradigm Selectronic 7025.1 Series

Page 1: ... other Assistance please call 844 CRT TEAM 844 278 8326 In Canada 1 800 387 0369 In Toronto Area only 1 905 306 1093 Paradigm Selectronic Integrated Faucet with Optional Above Deck Mixing SmarTherm MODEL NUMBERS 7025 1xx 702B 1xx 7025 2xx 702B 2xx 7025 3xx 702B 3xx CAUTION Use only American Standard supplied transformers and cable sets Using non AS supplied cables or cutting splicing or modifying ...

Page 2: ...MAC PK00 BBU Battery Back Up Kit 7 POWER KITS SOLD SEPARATELY 702P 400 Paradigm 4 605XTMV1070 4 Mixing Valve 3 6 1 1 2018 AS America Inc Ins t al l at i on Inst ruction s 2018 AS America Inc NOTE TO INSTALLER Please give this manual to the customer after installation To learn more about American Standard Selectronic Products visit our website at www americanstandard us com or e mail us at CRTTEAM ...

Page 3: ...n 2 If installing DECK PLATE 2 optional Apply a bead of putty to bottom edge of PUTTY PLATE 2 Install SCREW 11 into the MOUNTING BASE OF THE FAUCET 13 and allign SCREW 11 with HOLE 12 3 Insert SUPPLY HOSES 3 SHANK 4 and SENSOR CABLE 5 only included in base model through hole in DECK PLATE with PUTTY PLATE 2 and mounting surface 4 Assemble RUBBER WASHER 7 BRASS WASHER 8 and THREADED LOCKNUT 9 onto ...

Page 4: ...CE 3 as shown Rotate the END CAPS 4 to secure the connection within the CONNECTOR LOCKING DEVICE 3 3 Determine the mounting location of the PWRX BATTERY PACK 1 by marking center lines as shown 4 Place the BRACKET 5 on the horizontal center line and mark the location of the mounting holes to be drilled 5 Using 1 4 diameter drill bit drill two mounting holes aproximately 1 deep 6 Install the two ANC...

Page 5: ...sets Using non AS supplied cables or cutting splicing or modifying any components will void the warranty B AC VERSIONS HARD WIRED PLUG IN POWER SUPPLY Fig 2 Important Turn off power to outlet or electrical box FOR PLUG IN VERSION 1 Connect PLUG IN AC POWER SUPPLY 2 to one end of the SINGLE AC ADAPTER 6 2 Connect SENSOR CABLE 4 to the other end of the SINGLE AC ADAPTER 6 3 Connect PLUG IN AC POWER ...

Page 6: ...emoving the handle preset the desired water temperature and while disassembling make sure to keep the SHAFT EXTENSION 8 in place 1 Unthread SET SCREW 3 and remove HANDLE 5 2 Remove LIMIT STOP 1 3 Using a Slotted screwdriver unthread SCREW 7 and remove SHAFT EXTENSION 8 Note Hold the extension in place while unthreading the screw 4 Install CAP 9 onto the Body and press until you hear a click Note S...

Page 7: ...t COVER 15 off 2 Disconnect SENSOR CABLES 6 and 7 from the BATTERY and SOLENOID VALVE Fig 9 3 Push BATTERY 17 forward and Pull it out Fig 8 4 Replace the new battery with the same placement Insert terminal side first C CHANGE SENSOR RANGE Fig 8 9 1 Remove 3 COVER SCREWS 1 2 Remove the COVER 15 3 Disconnect the BLACK POWER SUPPLY CONNECTOR 7 and reconnect Fig 9 4 While the SENSOR CONTROL LED 9 is b...

Page 8: ... 4 WARNING Do not turn the THERMO VALVE 4 More than 1 turn The maximum mixed water temperature can not be increased due to ASSE 1070 requirements E GENERAL CLEANING 1 Only use a damp soft cloth to clean the spout and the sensor 2 For tougher dirt use a soft cloth with diluted dish washing detergent Wipe the area using a wet cloth and dry using a soft cloth CAUTION Do not scratch the sensor when cl...

Page 9: ...XTERNAL SUPPLY STOPS CRITICALLY LOW BATTERY INSTALL NEW BATTERY DEAD BATTERY INSTALL NEW BATTERY REPEAT NO CHECK FOR DAMAGE TO SENSOR WIRE INSULATION REPLACE SENSOR ARE EXTERNAL SUPPLY STOPS OPEN REPEATED DOUBLE FLASH ON SENSOR RECONNECT BATTERY TO SENSOR DOES SENSOR FLASH FOR 5 SECONDS REPLACE SOLENOID YES YES NO CHECK FOR DAMAGE TO SENSOR WIRE INSULATION REPLACE SENSOR RECONNECT BATTERY TO SENSO...

Reviews: