100
18-CE03D1-1F-EN
Integrated Furnace Control Display Codes
2 Stage Inducer with ECM Blower Motor
IdL
Idle
XtI
First Stage Gas Heating
Lr1
First Stage Gas Heat Learning Routine
Xt2
Second Stage Heating
Lr2
Second Stage Gas Heat Learning Routine
aRF
Airflow (Followed by Airflow times 10)
C0F
Continuous Fan
CLI
First Stage Cooling
CL2
Second Stage Cooling
Xp!
First Stage Heat Pump
Xp2
Second Stage Heat Pump
dFt
Defrost Mode
Menu Options
err
Active Alarm Menu
L6F
Last 6 Faults (To clear — Hold Option button down for 5 seconds)
Cr
Code Release Number
C0d
Cooling Off Delay (Seconds)
0dt
Outdoor Tonnage
0du
Outdoor Unit
COF
Blower Constant Fan Airflow Multiplier (Percentage)
CpC
Cooling (CFM/Ton)
CpH
Heat Pump Heating (CFM/Ton)
Xod
Heat Off Delay (Seconds)
!sd
Inter-Stage Delay (Seconds)
gXC
Gas Heating CFM 2nd Stage (1st Stage is not adjustable) (Airflow times 10)
run
Run Test Mode