background image

INSTALLATION INSTRUCTIONS

791031-100 Rev. H

© American Standard Inc. 2005
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.

AMERICAST BRAND 
ENGINEERED MATERIAL

STRATFORD™ 

WHIRLPOOL/BATHING POOL

2470.XXXW SERIES

FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.

T H A N K     Y O U . . .

for selecting an American Standard bath. Your new 
bath is shipped to you after careful inspection. The 
whirlpool version is completely assembled with pump, 
motor, and system piping. All you need to finish the 
installation are your selected fittings and electrical 
connections for a whirlpool.

To insure maximum performance and pleasure from 
this product, please follow the instructions and 
cautions. 

GENERAL INSTALLATION INFORMATION

Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor 
immediately.

After inspection and during installation, protect the bath from construction damage. After installation, and before 
enclosing with wallboard, tile, etc., water test the unit and check for leaks.

Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect 
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump, 
motor, or piping system.

Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and 
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead 
(required for recess installations).

Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.  

WARNING! Do not lift whirlpool by the piping harness at any time.

List of Optional Components (not included):
•  Safe-T-Heater 9075.120*
•  Tile Bead Kit 751755-100*

see your American Standard Distributor

List of Required Components (not included):
•  Drain 1583.470*
•  Bath Filler* 

* see your American Standard Distributor

List of Required Tools and Supplies:

Tools
•  Level
•  Tape Measure
•  Pipe Wrench
•  Slip Joint Pliers
•  Screw Driver
•  Standard
      Woodworking Tools
•  Personal Safety
      Equipment
•  Caulking Gun

Supplies
•  Nails
•  Putty
•  Caulking (waterproof)
•  1 x 3 or 2 x 4
      Stringers
•  Drop Cloth
•  15 amp GFCI
      Outlet
•  Cement, Plaster,
      Grout

203mm

(8)

1676mm

(66)

813mm

(32)

PROVIDE ACCESS

TO PUMP FOR

SERVICING

ON ALL 

INSTALLATIONS

235mm

(9-1/4)

406mm

(16)

OUTLINE OF 1638 X 775mm
(64-1/2 X 30-1/2) CUTOUT

19mm
(3/4)

C/L OF 1/2
SUPPLIES

AS  REQUIRED

FINISHED
WALL

PUMP

ON/OFF

SWITCH

32mm
(1-1/4)

C/L OF DRAIN
       OUTLET

229 X 305mm
(9 X 12) FLOOR CUTOUT

508mm

(20)

476mm

(18-3/4)

MIN.

32mm 
(1-1/4)

1-1/2 N.P.T. THREADS

1-1/2 O.D. TAILPIECE

70mm

(2-3/4)

117mm (4-5/8)

SUPPORT 
STRINGER

324mm

(12-3/4)

102mm
(4)

711mm

(28)

32mm (1-1/4) DIA. HOLE 
1/2 N.P.T. SHOWER

44mm (1-3/4) DIA. HOLES
FOR CONTROL VALVES

32mm (1-1/4) DIA. HOLE FOR 
1/2 N.P.T. SPOUT

203mm
 (8)

1651-1982mm

(65-78) 

OPTIONAL

1/2 SUPPLIES

AS REQ'D

C/L OF SHOWER

CURTAIN ROD

1930mm (76)

OPTIONAL
TO FLOOR

70mm

(2-3/4)

FINISHED 
WALL

C/L OF
OVERFLOW

76mm

(3)

SAFE-T-HEATER

REMOVABLE BLANK

GENERAL SPECIFICATIONS FOR 2470 WHIRLPOOL

WHIRLPOOL ELECTRICAL SPECIFICATIONS

SYSTEM I PUMP

1.6 HP, 9.7 AMPS,120V.

66 x 32 x 20 In. (1676 x 813 x 508mm)

201 Lbs. (90 Kg.)

701 Lbs. (315 Kg.)

60 Gal. (227 L)
40 Gal. (152 L)

42 x 19 In. (1067 x 483mm)
60 x 27 In. (1524 x 686mm)

14 In. (356mm)

55 Lbs./Sq.Ft. (223 Kgs./Sq.m)

13.9
33.7

INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT

3

)

Summary of Contents for Stratford Whirlpool/Bathing Pool 2470.XXXW

Page 1: ...llation using a drop cloth WARNING Do not lift whirlpool by the piping harness at any time List of Optional Components not included Safe T Heater 9075 120 Tile Bead Kit 751755 100 see your American Standard Distributor List of Required Components not included Drain 1583 470 Bath Filler see your American Standard Distributor List of Required Tools and Supplies Tools Level Tape Measure Pipe Wrench S...

Page 2: ...REQUIRE FRAMING PROCEDURES OTHER THAN THOSE SHOWN LOCATE STUDS AS REQUIRED INSURE ROUGH DIMENSIONS ARE PROPER PLUMB AND SQUARE FOR WHIRLPOOLS PROVISION MUST BE MADE IN ALL INSTALLATIONS FOR AN ACCESS OPENING FOR SERVICING PUMP AND CONTROLS STRINGER OR PIER HEIGHT SHOULD BE AS INDICATED NO ADDITIONAL SUMP SUPPORT IS REQUIRED ANY FINISH MATERIAL SUCH AS TILE OR WALLBOARD MUST BE SELF SUPPORTING IF I...

Page 3: ...RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a ground fault circuit interrupter 2 Grounding is required The unit should be installed by a licensed electrician and grounded 3 Install to permit access for servicing 4 All building materials and wiring should be routed away from the pump body and heater if equipped The whirlpool should be installed on a 120 vac 15 amp dedicated circui...

Page 4: ...en popsicle stick or tongue depressor Do not use wire brushes or any other metal implement on bath surface Post installation clean up generally can be completed using warm water and liquid dishwashing detergent Stubborn dirt or stains may be removed using granular Spic and Span mixed with water Painter s naphtha can be used to remove excess adhesives and or wet oil base paint HARSH CHEMICALS SHOUL...

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ......

Reviews: