INSTALLATION INSTRUCTIONS
791031-100 Rev. H
© American Standard Inc. 2005
All product names listed herein are trademarks
of American Standard Inc. unless otherwise noted.
AMERICAST BRAND
ENGINEERED MATERIAL
STRATFORD™
WHIRLPOOL/BATHING POOL
2470.XXXW SERIES
FOR AFTER-SALES SERVICE CALL 1 (800) 442-1902 WEEKDAYS.
T H A N K Y O U . . .
for selecting an American Standard bath. Your new
bath is shipped to you after careful inspection. The
whirlpool version is completely assembled with pump,
motor, and system piping. All you need to finish the
installation are your selected fittings and electrical
connections for a whirlpool.
To insure maximum performance and pleasure from
this product, please follow the instructions and
cautions.
GENERAL INSTALLATION INFORMATION
Carefully uncrate and inspect your new bath for any shipping damage. If such damage is found, report it to your vendor
immediately.
After inspection and during installation, protect the bath from construction damage. After installation, and before
enclosing with wallboard, tile, etc., water test the unit and check for leaks.
Do not make modifications to the whirlpool system or remove pump from factory mounting. This could adversely affect
the safety and performance of the whirlpool and void the warranty. Do not handle or move the whirlpool by the pump,
motor, or piping system.
Fittings (bath filler, shower arm, etc.) are not provided with the bath and must be ordered separately. Framing and
enclosing materials are provided by others. Check for availability of optional American Standard wall tiling bead
(required for recess installations).
Protect all finished surfaces of the whirlpool during construction and installation using a drop cloth.
WARNING! Do not lift whirlpool by the piping harness at any time.
List of Optional Components (not included):
• Safe-T-Heater 9075.120*
• Tile Bead Kit 751755-100*
* see your American Standard Distributor
List of Required Components (not included):
• Drain 1583.470*
• Bath Filler*
* see your American Standard Distributor
List of Required Tools and Supplies:
Tools
• Level
• Tape Measure
• Pipe Wrench
• Slip Joint Pliers
• Screw Driver
• Standard
Woodworking Tools
• Personal Safety
Equipment
• Caulking Gun
Supplies
• Nails
• Putty
• Caulking (waterproof)
• 1 x 3 or 2 x 4
Stringers
• Drop Cloth
• 15 amp GFCI
Outlet
• Cement, Plaster,
Grout
203mm
(8)
1676mm
(66)
813mm
(32)
PROVIDE ACCESS
TO PUMP FOR
SERVICING
ON ALL
INSTALLATIONS
235mm
(9-1/4)
406mm
(16)
OUTLINE OF 1638 X 775mm
(64-1/2 X 30-1/2) CUTOUT
19mm
(3/4)
C/L OF 1/2
SUPPLIES
AS REQUIRED
FINISHED
WALL
PUMP
ON/OFF
SWITCH
32mm
(1-1/4)
C/L OF DRAIN
OUTLET
229 X 305mm
(9 X 12) FLOOR CUTOUT
508mm
(20)
476mm
(18-3/4)
MIN.
32mm
(1-1/4)
1-1/2 N.P.T. THREADS
1-1/2 O.D. TAILPIECE
70mm
(2-3/4)
117mm (4-5/8)
SUPPORT
STRINGER
324mm
(12-3/4)
102mm
(4)
711mm
(28)
32mm (1-1/4) DIA. HOLE
1/2 N.P.T. SHOWER
44mm (1-3/4) DIA. HOLES
FOR CONTROL VALVES
32mm (1-1/4) DIA. HOLE FOR
1/2 N.P.T. SPOUT
203mm
(8)
1651-1982mm
(65-78)
OPTIONAL
1/2 SUPPLIES
AS REQ'D
C/L OF SHOWER
CURTAIN ROD
1930mm (76)
OPTIONAL
TO FLOOR
70mm
(2-3/4)
FINISHED
WALL
C/L OF
OVERFLOW
76mm
(3)
SAFE-T-HEATER
REMOVABLE BLANK
GENERAL SPECIFICATIONS FOR 2470 WHIRLPOOL
WHIRLPOOL ELECTRICAL SPECIFICATIONS
SYSTEM I PUMP
1.6 HP, 9.7 AMPS,120V.
66 x 32 x 20 In. (1676 x 813 x 508mm)
201 Lbs. (90 Kg.)
701 Lbs. (315 Kg.)
60 Gal. (227 L)
40 Gal. (152 L)
42 x 19 In. (1067 x 483mm)
60 x 27 In. (1524 x 686mm)
14 In. (356mm)
55 Lbs./Sq.Ft. (223 Kgs./Sq.m)
13.9
33.7
INSTALLED SIZE
WEIGHT
WEIGHT w/WATER
GAL. TO OVERFLOW
WHIRLPOOL MIN. OPERATING VOL.
BATHING WELL AT SUMP
BATHING WELL AT RIM
WATER DEPTH TO OVERFLOW
FLOOR LOADING
(PROJECTED AREA)
PTS.
CUBE (FT
3
)