background image

INDEX

A. TIM-615: GENERAL OVERVIEW

1) LCD Display

2) User Buttons

3) Measurement Chamber

4) Batteries

B. INSTALLATION
C. DAILY USE
D. CALIBRATION

1) Definitions

2) Reasons to Calibrate

3) Calibration Procedure

4) Display the K Factor & Restoring the

 Factory K Factor

5) In-Field Calibration

6) Direct Calibration of the K Factor

E. UNIT OF MEASURE SETUP
F. METER MAINTENANCE
G. TROUBLESHOOTING GUIDE
H. PARTS BREAKDOWN AND SPECIFICATIONS

A. AMERICAN LUBRICATION TIM-615: GENERAL OVERVIEW

TIM-615 is an electronic digital oval-gear meter, designed for precise 

measuring  of  oil  and  other  liquids  that  are  compatible  with  the 

materials  found  in  the  meter.  The  TIM-615  features  a  non-volatile 

memory for storing calibration and dispensing data in the event of 

a  complete  power  loss. The  meter  is  unique  in  that  the  electronic 

section is completely isolated from the fluid section. This means that 

the  electronics  can  be  easily  field  replaced  while  the  meter  is  still 

installed in-line using a replacement electronics “head”.

1) LCD Display 

The “LCD” of the TIM-615 features two numerical registers and 

various symbols that are displayed only when required.

Batch register indicates volume dispensed
Battery charge Indicator
Calibration Mode
Total register; display can show (2) different totals, 

one  which  is  resettable  and  one  that  is  non-

resettable. 
Total multiplication factor ( x10 or x100 )
Total type (TOTAL / RESET TOTAL)
Total unit of measurement (Gal=Gallons, L=Liters)
Batch unit of measurement (Qts=Quarts, Pts=Pints, 

L=Liters, Gal=Gallons

2) User Buttons

The  TIM-615  meter  features  two  buttons  (RESET  and  CAL  ) 

which individually perform two main functions and when pressed 

at  the  same  time  together  perform  secondary  functions.  The 

functions are:

For  the  RESET  button,  resetting  the  batch  register  and  the 

resettable totalizer. 
For the CAL button, entering meter calibration mode.

Pressing RESET and CAL together enters the configuration 

mode where the desired unit of measurement can be set.

3) Fluid Chamber

The  measurement  chamber  is  located  in  the  lower  part  of  the 

meter. It features a 1/2” NPT(F) inlet and outlet. The cover on the 

bottom provides access to the chamber for contaminate cleaning. 

Inside the chamber are two oval gears that generate electrical 

pulses which are counted by the microprocessor. By applying a 

calibration factor, the microprocessor translates the pulses into 

units of measurement, displayed on the batch and total registers 

of the LCD. All TIM-615’s are factory set with a calibration factor 

(FACTORY K FACTOR) equal to 1,000.

4

5 6

8

7

1

2

3

2. Reasons to Calibrate

The TIM-615 is supplied with a factory calibration that ensures 

precise measuring in most operating conditions. Meter accuracy 

might be compromised when dispensing fluids like low-viscosity 

automatic  transmission  fluid  or  high-viscosity  gear  oils.  The 

meters’ accuracy also might be compromised when operating at 

flow rates that are close to the minimum or maximum.

When the meter’s accuracy is less than ideal, user calibration can 

be performed to better suit the actual conditions in which the TIM-

615 is required to operate.

3. Calibration Procedure

Two  procedures  are  available  for  changing  the  Calibration 

Factor:

Dispensing Calibration, performed by means of a dispensing 

operation.
Direct  Calibration,  performed  by  directly  changing  the 

calibration factor inside the meter.

The calibration phases can be entered (by keeping the CAL button 

pressed for a few seconds) to:

Display the current user calibration factor

Return to factory calibration (Factory K Factor) after a previous 

calibration by the user

Change the calibration factor using one of the two previously 

indicated procedures.

During  calibration,  the  batch  and  total  dispensed  quantities 

indicated 

on  the  display  screen  take  on  different  meanings 

according to the calibration procedure phase. 

In  calibration  mode,  the  TIM-615  cannot  be  used  for  normal 

dispensing operations. During the calibration process, the totals 

are not increased.

4. Displaying the K Factor & Restoring the Factory K Factor

By pressing the CAL button while the meter is in standby mode, 

one  of  two  display  pages  will  appear  showing  the  current 

calibration factor. 

The  following  display  page  will  appear  if 

calibration has been performed or the meter 

has  been  restored  to  factory  calibration. 

The  word  “FACT”  (abbreviation  for  “factory”) 

indicates that the factory calibration factor is 

being used.

This  display  page  will  appear  if  a  calibration 

has  been  made  by  the  user.  It  shows  the 

current used calibration factor (in the example 

0.998)  and  the  word  “USER”  (indicating  that 

the user calibration factor is being used)

The flow chart shows 

the  switch-over  logic 

from one display page 

to another

In  this  condition,  the 

Reset  button  permits 

switching  from  the 

User  factor  to  the  

Factory factor.

To confirm the choice 

of  the  calibration 

factor,  quickly  press 

the CAL  button while 

“USER”  or  “FACT” 

are displayed.

After the restart cycle, 

the  TIM-615  uses 

the  calibration  factor 

that  had  just  been 

confirmed

5. In-Field Calibration

This  procedure  requires  the  fluid  to  be  dispensed  into  a  certified 

graduated container. For best accuracy, perform this procedure when 

the meter is installed in the system it is going to be used on.

5. In-Field Calibration (continued)

ACTION

 DISPLAY

1

Make sure the meter is in standby mode

.

If you are unsure, press the REST button and wait 10 

seconds.

2

Hold  down  the  CAL  button  until  the  display  reads 

“CAL”.

The TIM-615 enters calibration mode, shows <<CAL>> and 

displays the calibration factor in use. The words “FACT” and 

“USER” indicate which of the two factors (factory or user) 

is currently in use.

3

Hold  down  the  RESET  button  until  the  display  reads 

“FIELD”.

The  TIM-615  shows  “CAL”  and  the  batch  register  set  to 

zero.  The  TIM-615  is  ready  to  perform  in-field  dispensing 

calibration.

4

Dispensing into a calibrated container.

Without pressing any buttons, start dispensing 

into the graduated container.

Dispensing can be stopped and started again 

at will. Continue dispensing until the level of 

the fluid in the sample container has reached 

the graduated area. 

Make sure dispensing is correctly finished before performing 

the next step.

5

Press the RESET button, and quickly release.

This  tells  the  meter  that  the  dispensing  is  finished.  To 

finish calibrating the meter, the value on the meter’s batch 

display  (example  9.800)  must  be  adjusted  to  equal  the 

actual amount in the calibrated container. In the bottom left 

part of the display an arrow appears (pointing upwards or 

downwards), that shows the direction (increase or decrease) 

that  the  value  on  the  batch  display  will  be  changed  when 

performing step 7.

6

Changing the Arrows direction in the display

Quickly  pressing  the  RESET  button  changes  the  arrows 

direction in the display. This operation can be repeated to 

alternate the direction of the arrow. 

7

Adjusting the Batch Display Value (

The  indicated  value 

changes in the direction indicated by the arrow)

1) The amount on the display changes one unit each

   time the CAL button is pressed quickly. 

2) The amount on the display changes continuously 

if  the  CAL  button  is  kept  pressed.  The  speed

 

   of  change  increases  the  longer  the  button  is 

held.

If you accidentally program the wrong value, repeat the 

operation starting from step number 6

8

Saving the New Calibration Factor

Before  performing  this  operation,  double-check  to  make 

sure the display value on the meter is the same value that is 

in the calibrated container.

Press the RESET button for at least one second. The TIM-

615 calculates the new USER K FACTOR. This calculation 

could require a few seconds to compute. At the end of the 

calculation, the new USER K FACTOR is shown for a few 

seconds. 

9

Finishing

The meter will re-start and enter into the standby mode. The 

meter  is  now  programmed  with  the  new  calibration  factor 

and is ready to use.

Note: The calibrated USER K FACTOR is now the factor 

used in the TIM-615. This will be the factor the meter will 

use even after battery failure and battery replacement.

CAL BUTTON

RESET 

BUTTON

LCD DISPLAY

a) For a few seconds after the RESET button is pressed. 

b) During the entire dispensing stage and for five seconds after

 dispensing.  Once  this  short  time  has  expired  the  TIM-615

   switches  to  standby  mode  and  the  lower  register  switches 

 back to the non-resettable total (TOTAL).

NOTE: 6 digits are available for TOTALS, plus two 

icons x 10 / x100. The increment sequence follows: 0.0 

→ 99999.9 → 999999 → 100000 x 10 → 999999 x 10 → 

100000 x 100 → 999999 x 100

!

!

NOTE: The TIM-615 features a non-volatile memory for 

storing calibration and dispensing data. There is no 

need to re-calibrate the meter in the event of power loss.

NOTE: When the Factory Factor is chosen, the old user 

factor is deleted from the memory

!

1) Completely eliminate all of the air from the system before calibrat- 

     ing.

2) Use a certified graduated container with a  minimum capacity of 

  5 Qts. Do not use metal or plastic oil containers typically found in 

 automotive shops. These are typically not accurate enough.

!

NOTE: Important steps for accurate meter calibration:

!

NOTE: Important steps for accurate meter calibration: 

(continued)

3)   Try to keep the flow rate constant when filling the container. Do

 

  not trickle the flow to reach the desired level (the correct method

 

  during the final stage is to make  short top-offs at the normal 

 

  operating flow rate).

4) When oil is dispensed into a container, air gets trapped 

 inside the oil, making the level in the container appear 

 higher than it really is. After dispensing, wait a few minutes 

 to make sure all air bubbles are eliminated from the fluid

 

 inside the calibration container. 

4) Batteries

The  TIM-615  is  powered  by  two  standard  AAA  1.5V  Alkaline 

batteries. The batteries can be found under the face of the meter 

by removing the four top screws and the protective cover.

B. INSTALLATION

The TIM-615 features two ½” NPT(F) ports. It has been designed to 

be installed in any position, in a  fixed in-line installation or as part 

of a control handle. The meter does not have  specific direction of 

flow and either port can be used as inlet or an outlet. Make sure 

the  threaded  connections  do  not  interfere  with  the  inside  of  the 

measurement chamber. This can cause the gears to be damaged 

and/or seize.  A filter with adequate filtering capacity should always 

be  placed  at  the  inlet  of  the  meter  or  somewhere  in  the  product 

line onto which the TIM-615 is mounted. If solid particles enter the 

measurement chamber, the gears could be damaged and/or seize.

C. DAILY USE

Below are the two normal display modes. One display page shows 

the batch and resettable total registers (temporary display mode). 

The  other  page  shows  the  batch  and  non-resettable  total  register 

(standby  display  mode).  Changeover  between  these  two  pages 

is automatic and tied to phases and times that are factory set and 

cannot be changed by the user.

*The  batch  register  is  in  the  top  of  the  display  and  indicates  the 

quantity  dispensed  since  the  last  time  the  RESET  button  was 

pressed
*The  resettable  total  register  (Reset

 

TOTAL),  positioned  in  the 

lower  part  of  the  display,  indicates  the  quantity  dispensed  since 

the  last  time  the  resettable  total  was  reset.  The  resettable  total 

cannot be reset until the batch register has been reset. The unit of 

measurement of the two total registers can be the same as the batch 

register or a different unit of measure depending on the factory or 

user programming choice.
*The non-resettable total register (TOTAL) can never be reset by the 

user. It continues to rise for the entire operating life of the TIM-615.
*The register of the two totals (Reset TOTAL and TOTAL) share the 

same line of the display. The TIM-615 is programmed to show each 

of these totals at different times.
*The  non-ressettable  (TOTAL)  page  is  shown  in  standby  screen 

mode
*The resettable total (Reset TOTAL) page is shown in the temporary 

screen mode:

1) Resetting the Batch Register 

The batch register can be reset by pressing the RESET button 

only when the meter is in standby mode. Press the RESET button 

to reset the batch register. After pressing the RESET button, the 

LCD  screen  will  display  all  the  characters  on  the  screen,  and 

then the screen will momentarily go blank. The screen will then 

display the resettable total for 5 seconds, after which the display 

will return to the standby mode screen.

2) Resetting the Resettable Total (Reset TOTAL)

Wait for the display to enter standby mode 

Press  the  RESET  button  quickly.  This  will  reset  the  batch

 

register.
After pressing the RESET button, the LCD screen will display 

all  the  characters  on  the  screen,  and  then  the  screen  will 

momentarily  go  blank.  The  screen  will  then  display  the 

resettable total for 5 seconds. Hold down the Reset button for 

at least one second.
The LCD screen will again display all the characters on the 

screen, and then the screen will momentarily go blank. The 

screen will then display the resettable total (which now should 

read 0.0) for 5 seconds

D. CALIBRATION

1. 

Definitions

Calibration factor or “K Factor” - this is the multiplication factor 

applied  by  the  system  to  the  electrical  pulses  received,  to 

transform these into measured fluid units.

Factory  K  Factor:  Factory-set  default  factor.  It  is  equal  to 

1,000.

The Factory K Factor is based on the following operating 

conditions:

User K Factor:

 Customized calibration factor, meaning the K 

Factor obtained from calibrating the meter.

Temporary Display Mode

Standby Display Mode

Batch Display 

Actual Value

Indicated Value

Real Value

1)
2)
3)
4)

5)
6)
7)
8)

a)

b)
c)

Fluid  

10W30 motor oil

Temperature:  

68° F.

Flow rate:  

1.3 - 6.6 gallons/min.

a)
b)

c)

d)

a)

b)

c)

a)

b)

a)

b)

c)

PRO SERIES

DIGITAL  OVAL GEAR METER

     TIM-615 

This  meter  is  built  exclusively  for  American 

Lubrication  Equipment  Corporation  incorporating 

numerous design ideas provided by their design team.

PRO SERIES METER 

PRO SERIES METER 

PRO SERIES METER

PRO SERIES METER 

PRO SERIES METER 

PRO SERIES METER 

PRO SERIES METER 

PRO SERIES METER 

PRO SERIES METER

PRO SERIES METER

PRO SERIES METER

PRO SERIES METER

PRO SERIES METER

Baltimore, Md.                Los Angeles, Ca.

410

-252-9300

americanlube.com

Features

Fluid Isolated from the Electronics
Field-Replaceable Electronic Head
Reliable Oval Gear Design
New AAA Ba

t

tery Lasts Longer

6 Bolt Construction
Programmable to Pts, Qts, Lts & Gals
Molded-in Shock Guard

Bulletin  M0169 EN rev.1

Bulletin  M0169 EN rev.1

The batch register (top 
row) can be reset; the total 
register (bottom row) 
cannot be reset (even if 
you take the batteries 
out). 

Summary of Contents for PRO TIM-615

Page 1: ...speed of change increases the longer the button is held If you accidentally program the wrong value repeat the operation starting from step number 6 8 Saving the New Calibration Factor Before performing this operation double check to make sure the display value on the meter is the same value that is in the calibrated container Press the RESET button for at least one second The TIM 615 calculates t...

Page 2: ...ies If you continue to use the meter without changing the batteries the second battery alarm level will eventually be reached preventing meter operation In this condition the battery icon will flash and will be the only item visible on the LCD You must change the batteries once the meter has reached this mode All dispensing data from this point forward will not be displayed or stored in the meter ...

Page 3: ...letters CAL FIELD appear Dispense 4 quarts of oil into your container Start and stop the flow as needed to reach the appropriate level in the container Press and hold the RESET button until an arrow appears in the lower left hand corner of the display It will read CAL Direct with an arrow pointing up If the total is under 4 quarts use this setting If the total is over 4 quarts press and release th...

Page 4: ...trigger to purge any air from your hose into the bucket 12 When you have a steady flow of oil coming out stop dispensing and close the non drip tip on the control handle 13 Dispose of the oil in the bucket into your waste drain Trouble Shooting Control Handles There is a display problem o Have you changed the batteries The meter is dispensing oil but not metering anything o Have you changed the ba...

Page 5: ...600 FMHF 7 Flex Manual Hi Flow TIM 743 1 TIM 600 RA 4 Rigid Automatic TIM 746 TIM 600 RM 2 Rigid Manual TIM 753 TIM 600 RMHF 6 Rigid Manual Hi Flow TIM 752 These tip assemblies have had their compression nuts Loctited at the factory during the assembly process We recommend placing a few drops of Loctite 680 Retaining Compound on the threads of the compression nut when replacing these tip assemblie...

Page 6: ...ng normal use Do not under any circumstances place Loctite on the threads that are used to fasten the tip assembly to the meter body Filter cleaning procedure 1 remove swivel 2 remove clean reinstall filter 3 reinstall swivel Model Number Tip Style Description Tip Assembly TIM 601 FA 3 Flex Automatic TIM 747 TIM 601 FM 1 Flex Manual TIM 743 TIM 601 RMGO 5 Swivel 90º Rigid Manual TIM 742 TIM 601 FM...

Page 7: ...airable The TIM 715 meter can be replaced with a new TIM 615 meter You can reuse your old extension nozzle and old control handle with the TIM 615 Please call 410 252 9300 and press 3 for pricing and availability The upper of numbers reset to zero after a battery replacement and should count up as oil is pumped through the meter The number in the lower right corner is not resettable ...

Reviews: