background image

11 

Summary of Contents for 00M10800

Page 1: ... Number 98 0100 Revision A SILEX DEIONIZER OPERATION MAINTENANCE MANUAL MODEL 00M10800 00M20800 00M30800 Manufactured With Pride In The USA www ameriwater com 800 535 5585 AmeriWater 3345 Stop 8 Rd Dayton OH 45414 ...

Page 2: ...About the resin pack 1 SILEX FEATURES 2 INSTALLATION COMMON SITUATIONS OF USE 3 INSTALLATION 10 EASY STEPS 4 RESIN PACK FILTER EXCHANGE 7 Resin Pack Exchange 7 Filter Cartridge Replacement 8 RESIN PACK REGENERATION 9 SYSTEM BUILD DRAWING 10 IWAKI PUMP 11 Installation 11 OperatingTips 11 Typical WMD MD Series Pumps Components 12 SILEX WARRANTY POLICY 13 ...

Page 3: ...system When the monitor light signals that the product water quality has dropped below the desired quality setpoint simply exchange the resin packs and send them to AmeriWater for regeneration NOTE AMERIWATER DOES NOT REGENERATE RESIN PACKS THAT HAVE BEEN USED IN HAZARDOUS WASTE APPLICATIONS HOW DOES THE REGERNERATION WORK The AmeriWater regeneration center maintains the resin used in the Silex De...

Page 4: ...2 SILEX FEATURES ...

Page 5: ...3 INSTALLATION COMMON SITUATIONS OF USE ...

Page 6: ...regulations If a drain is not feasible mount the system on a raised platform so that it can be drained into a container 3 It is recommended to install cut off valves on the inlet and outlet sides of each unit to facilitate changing of resin packs 4 Connect the inlet supply hose to the hose barb fitting on the left side of the system while facing the label Use the hose clamps provided with the syst...

Page 7: ...Pounds per Square Inch The maximum flow for each deionizer is 3 GPM Gallons Per Minute 7 Install the optional pre filter post filter and or monitors if applicable per the instructions provided with the optional equipment 8 Install the resin pack s a Remove the cover plates by unscrewing the four black knobs on each plate To break the seal between the cover plates and the upper plates use a slotted...

Page 8: ...two corners e Close the drain valve at the bottom of the column f Repeat steps a through e for each of the columns 9 Open the air vents located on the top of the cover plates and turn on the water supply Tighten the air vents closed when water begins to escape through the vents 10 Allow several gallons of water to run through the Silex system Continue running water through the system until the wat...

Page 9: ...rom the shipping box and open the tied end of the plastic sleeve Stretch the resin pack over your arm to elongate the pack Feed the pack into the column allowing it to slide out of the plastic sleeve Save the plastic sleeve for the return shipment of the resin pack at the next exchange in non hazardous applications 8 Carefully wipe the O rings and the grooves on the top plate and cover plate to re...

Page 10: ...ter housing Close the filter drains when water ceases to flow out of them 3 Use the filter wrench supplied in the installation kit to turn the filter housing counterclockwise 4 Remove and discard the old filter cartridge s 5 Partially unwrap the plastic from the new filter cartridge Holding the end covered in plastic place the new filter cartridge in the housing Discard the plastic wrapper after i...

Page 11: ...d address 2 When you send each pack to AmeriWater enclose the regeneration certificate in the box AmeriWater will ship you a freshly regenerated resin pack 3 To order more certificates contact the company that originally sold you the deionizer 4 It is recommended to send the exhausted resin to AmeriWater immediately after exchange This will allow time for shipment and will maintain your uninterrup...

Page 12: ...10 ...

Page 13: ...11 ...

Page 14: ...12 ...

Page 15: ... warranty service notice must be given to the manufacturer within 30 days of the discovery of the defect There are no warranties on the SILEX system beyond those specifically described above All implied warranties including any implied warranty of merchantability or of fitness for a particular purpose are disclaimed to the extent they might extend beyond the above periods The sole obligation of th...

Page 16: ...a to cause cancer birth defects or other reproductive harm One such chemical is Vinyl Chloride a compound used to produce Polyvinyl Chloride PVC The AmeriWater system you have purchased may contain PVC or stainless steel parts While warnings are only required in the State of California AmeriWater has initiated the use of Prop 65 labeling for all products to ensure compliance with California regula...

Reviews: