Page 10
For technical questions, please call 1-888-866-5797.
Item 64014
SaFEty
OpEra
tiOn
MaintEnancE
SEtup
Measurement Operation
note:
Remove plugs from
ends of Test Leads (included)
before connecting to Meter.
note:
Test Lead probes have removable
covers for overvoltage protection. With
covers in place, Test Leads are rated for
use with CAT III circuits. Exposed probes
are rated for use with CAT II circuits.
ac/Dc Voltage Measurement
Measure AC conductors carrying up to 600 VAC, from 40 Hz to 400 Hz.
Measure DC conductors carrying up to 600 VDC.
WarninG!
Use caution when working
near voltages above 30 VAC rms,
42 VAC peak, or 60 VDC. Voltages this
high present a risk of electric shock.
WarninG!
To prevent damage
to the Meter or personal injury, do
not measure voltages higher than
600 VDC or 600 VAC rms.
1. Plug black test lead into
cOM
Jack.
Plug red test lead into
input
Jack.
2. Turn Rotary Switch to the
position.
3. Press
Func
Button to choose
between AC and DC voltage.
4. While observing polarity, carefully
touch exposed conductors
with tips of probes.
5. Read measured voltage on the Display.
•
″
OL
” displayed on the Meter
indicates the measurement
exceeds the current range.
6. When testing is complete, turn
Rotary Switch to
OFF
, remove
Test Leads and store with Meter.
temperature Measurement
Measure temperature from -4°F to 1382
°
F (-20°C to 750
°
C).
1. Connect red end of Thermocouple
(included) to the
input
Jack and
the black end to the
cOM
Jack.
2. Turn Rotary Switch to the
temp
position. The Display will show
the current ambient temperature.
Press
Func
to switch between
Celsius and Fahrenheit.
3. Touch the tip of the Thermocouple
to the object to be tested.
4. Read measured temperature
on the Display.
5. When is complete, turn Rotary
Switch to OFF remove Thermocouple
and store with Meter.
WarninG!
To prevent electric
shock, remove Thermocouple before
switching between testing modes.