User Manual
i Series / iX Series
269
Test No.
Section
Subject
Test Limits
Comment
File Ref.
SAC603
Phase Reversal
Phase reversal done physically FSAC603
Table TAC:
Test No. Section
Subject
Test Limits
Comment
File Ref.
TAC101
Three Phase Load and Current Harmonic Measurements
115V RMS, 400 Hz
FTAC101
TAC102
Steady State Limits for Voltage (Including Unbalance) and Frequency
1
Balanced Phases
108V to 118V RMS, 393 to 407 Hz
Apply for 30 mins each test
FTAC102-1
2
Unbalanced Phases
108V to 118V RMS, +/- 3V Unbalance
Apply for 30 mins each test
FTAC102-2
TAC103
Voltage Phase Difference
Phase B 116 to 124 degrees
Apply for 30 mins each test
FTAC103
TAC104
Voltage Modulation
1
115V Nominal Test
115V RMS, 2.5V RMS mod
Apply for 10+ mins
FTAC104-1
2
109V Nominal Test
109V RMS, 2.5V RMS mod
Apply for 10+ mins
FTAC104-2
3
117V Nominal Test
117V RMS, 2.5V RMS mod
Apply for 10+ mins
FTAC104-3
TAC105
Frequency Modulation
1
400 Hz Nominal Test
400 Hz, 4 Hz mod
Apply for 10+ mins
FTAC105-1
2
395 Hz Nominal Test
395 Hz, 4 Hz mod
Apply for 10+ mins
FTAC105-2
3
405 Hz Nominal Test
405 Hz, 4 Hz mod
Apply for 10+ mins
FTAC105-3
TAC106
Voltage Distortion Spectrum
Requires Additional Equipment
TAC107
Total Voltage Distortion
Voltage Distortion Factor 0.05
Apply for 30 mins
FTAC107
TAC108
DC Voltage Component
1
Positive DC Offset
115V RMS + .10V DC
Apply for 30 mins
FTAC108-1
2
Negative DC Offset
115V RMS - .10V DC
Apply for 30 mins
FTAC108-2
TAC109
Normal Voltage Transients
180V RMS to 80V RMS
1
Overvoltage Transients
Peak voltage 180V RMS
Table TAC109-3 AA-GG
FTAC109-1
2
Undervoltage Transients
Low voltage 80V RMS
Table TAC109-3 HH-LL
FTAC109-2
3
Combined Transient
180V RMS to 80V RMS
Table TAC109-3 MM
FTAC109-3
4
Repetitive Normal Voltage Transient Test
90V RMS to 140V RMS
Run transient for 30 mins
FTAC109-4
TAC110
Normal Frequency Transients
375 Hz to 425 Hz
1
Overfrequency Transients
High Frequency 425 Hz
Table TAC110-3 AA-DD
FTAC110-1
2
Underfrequency Transients
Low Frequency 375 Hz
Table TAC110-3 EE-HH
FTAC110-2
3
Combined Transient
375 Hz to 425 Hz
Table TAC110-3 II
FTAC110-3
TAC201
Power Interrupt
0V for 50 msec
Table TAC201-2 A-L
FTAC201
TAC301
Abnormal Steady State Limits for Voltage and Frequency
100V RMS to 125V RMS, 380 Hz to 420
Hz
Apply for 30 mins
FTAC301
TAC302
Abnormal Voltage Transients
45V RMS to 180V RMS
1
Overvoltage Transients
Peak voltage 180V RMS
Table TAC302-3 AA-GG
FTAC302-1
2
Undervoltage Transients
Low voltage 45V RMS
Table TAC302-3 HH-NN
FTAC302-2
3
Combined Transient
45V RMS to 180V RMS
Table TAC302-3 OO
FTAC302-3
TAC303
Abnormal Frequency Transients
320 Hz to 480 Hz
Table TAC303-3 AA-EE
FTAC303
TAC401
Emergency Steady State Limits for Voltage and Frequency
Perform Test TAC102
TAC501
No Tests
N/A to AC Utilization Equipment
TAC601
Power Failure (Three Phase)
0V for 7 seconds
Table TAC601-2 A-D
FTAC601
Summary of Contents for 10001i
Page 2: ......
Page 3: ......
Page 6: ...ii This page intentionally left blank...
Page 38: ...User Manual 24 i Series iX Series Figure 3 5 Rear Panel View for the 3001i 3001iX...
Page 39: ...User Manual i Series iX Series 25 Figure 3 6 Rear Panel View for the 5001i 5001iX...
Page 43: ...User Manual i Series iX Series 29 Figure 3 8 Functional Test Setup...
Page 44: ...User Manual 30 i Series iX Series Figure 3 9 Single Phase 10000 VA System 10001iX i...
Page 46: ...User Manual 32 i Series iX Series Figure 3 11 Single Phase 15000 VA System 15001iX i...
Page 48: ...User Manual 34 i Series iX Series Figure 3 13 Connection With MODE Option...
Page 118: ...User Manual 104 i Series iX Series Figure 5 2 Power Source Module Block Diagram...
Page 121: ...User Manual i Series iX Series 107 Figure 5 3 5001i Internal Layout...
Page 122: ...User Manual 108 i Series iX Series Figure 5 4 Logic Board LED s...
Page 124: ...User Manual 110 i Series iX Series Figure 5 5 AC Power Stage Layout...
Page 125: ...User Manual i Series iX Series 111 Figure 5 6 AC Control Logic Block Diagram...
Page 138: ...User Manual 124 i Series iX Series Figure 6 3 Adjustment Location...
Page 152: ...User Manual 138 i Series iX Series Figure 9 4 Voltage Modulation...
Page 219: ...User Manual i Series iX Series 205 Figure 9 36 Example Connection With 5001iX and EOS 1...
Page 221: ...User Manual i Series iX Series 207 Figure 9 38 15003iX CTS EOS3 LR3...
Page 222: ...User Manual 208 i Series iX Series Figure 9 39 15003iX 3 EOS3...
Page 233: ...User Manual i Series iX Series 219 Figure 9 41 Example Connection With MODE iX...
Page 240: ...User Manual 226 i Series iX Series Figure 9 42 Example Connections With OMNI 1 18i...
Page 241: ...User Manual i Series iX Series 227 Figure 9 43 Example Connections With OMNI 3 18i...