March 2011
RP Series
58
14.2.4. Limit Subsystem
This subsystem controls the voltage frequency and current limit of the power source. These
limits are set at the factory and depend on the power source rating. It is not accessible by the
user. The query format is accessible however.
Subsystem Syntax
LIMit:
FREQuency:
LOW?
Queries the lower frequency limit
HIGH?
Queries the upper frequency limit
VOLTage?
Queries the upper voltage limit
CURRent?
Queries the upper current limit
LIMit:FREQuency:LOW?
This command queries the lower frequency limit of the power source.
Command Syntax
LIMit:FREQuency:LOW <NRf>
Parameters
Low freq limit [command protected]
Query Syntax
LIMit:FREQuency:LOW?
Returned Parameters
<NR2>
LIMit:FREQuency:HIGH?
This command queries the upper frequency limit of the power source.
Command Syntax
LIMit:FREQuency:HIGH <NRf>
Parameters
High freq limit [command protected]
Query Syntax
LIMit:FREQuency:HIGH?
Returned Parameters
<NR2>
LIMit:CURRent?
This command queries the maximum current limit the power source will operate at in the low
voltage range.
Command Syntax
[SOURce:]LIMit:CURRent <NRf>
Parameters
maximum current limit at low voltage range
[command
protected]
Query Syntax
LIMit:CURRent?
Returned Parameters
<NR2>
Summary of Contents for 1251RP Series
Page 2: ......
Page 3: ......
Page 4: ......
Page 6: ...ii This page intentionally left blank ...
Page 12: ......
Page 40: ...March 2011 RP Series 28 Figure 6 3 Location of Internal Adjustments ...