RP Series
March 2011
5
2.1.5.
Unit protection
Input Overcurrent:
Electronic current limit with fuse.
Input Overvoltage
Transients:
Surge protection to withstand EN50082-1 (IEC 801-4, 5) levels.
Output Overcurrent:
Shutdown, 0.1 second after overcurrent.
Output Overvoltage:
Shutdown, recycle input power to reset.
Output Short Circuit:
Peak current limit. Shutdown after 0.1 seconds.
Overtemperature:
Automatic shutdown.
2.2.
Mechanical
Dimensions:
16.51”(419.4mm) width x 3.5”(88.9 mm) height x 22”(558.8mm)
depth chassis size stand-alone configuration.
Unit Weight:
37 lbs.
Material:
Aluminum chassis, panels and cover.
Finish:
Yellow iridite then painted semi-gloss polyurethane
Cooling:
Fan cooled with air intake on the sides and exhaust to the rear.
Internal Construction: Modular sub assemblies.
Chassis Slides:
General Devices C300S-118-B308 (use hardware provided to
prevent damage to unit)
Front Panel Mounted
Output Connections:
CEE 7/7
European socket
US domestic
Single 5-15R 120V line socket
Rear Panel Mounted
Connections:
RS232C
Interface
DB 9
IEEE-488
Interface
D-shell 24 pin
Output
Phoenix Contact HDFK4
Line Input
IEC 320