REMOTE VOLTAGE PROGRAMMING
Remote voltage programming configuration is used for applications that
require the output voltage be programmed (controlled) from a remote
source. An external resistance or external voltage source may be used
as a programming device. When using remote voltage programming, a
shielded, twisted-pair, hookup wire is recommended to prevent noise
interference with programming signals.
3.5.1
EXTERNAL VOLTAGE PROGRAMMING USING RESISTANCE
The resistance coefficient for remote voltage programming is 5k
ohms/100% of rated output voltage with respect to the VP RTN, J1-20.
The programming current from terminal J1-21 (VP-RES) is factory set to 1
milliampere. This yields a coefficient of 1.0% of rated output voltage for
each 50 ohms. If multiple switches or relays are used to program different
levels, make-before-break contacts are recommended.
Note
: If an external resistance is used for remote programming, the
voltage programming return (VP RTN), terminal J1-20, must be
connected directly to or within ±3 volts (see note) of the power supply
common terminal, J1-24 See Figure 3-11 for connection requirements.
1
13
14
20 VP RTN
21 VP RES
COM 6
0-5 Kohms
PROGRAM
Figure 3-11. Remote Voltage Programming Using Resistance
Summary of Contents for AMREL SPS-A Series
Page 2: ......
Page 3: ......
Page 4: ......
Page 6: ...ii This page intentionally left blank ...
Page 8: ...iv This page intentionally left blank ...
Page 10: ...vi This page intentionally left blank ...
Page 16: ...CONTENTS AMREL SPS A Series vi M550129 01 Rev A This page intentionally left blank ...
Page 22: ...Overview AMREL SPS A Series 1 6 M550129 01 Rev A This page intentionally left blank ...
Page 42: ......
Page 71: ...AMREL SPS A Series Operation M550129 01 Rev A 3 29 This page intentionally left blank ...
Page 72: ......
Page 76: ...Maintenance AMREL SPS A Series 4 4 M550129 01 Rev A This page intentionally left blank ...