CBA Manual: H012161 Rev: 3
17
7.3
RF output N-Type or 7/16 (Model Dependent)
i
i
WARNING!
High RF voltages can occur on the inner conductor of the RF-out
connector, which could cause RF burns if touched. Do not expose
the centre pin to static discharge.
The nominal RF output impedance of the amplifier is 50 ohms, but it will safely drive a
load with an input impedance other than 50 ohms (resistive or reactive), but will deliver
less power. Refer to the specification sheet for details of RF output power.
7.4
Sample Ports, N-TYPE Female
These allow monitoring of both the incident power (P
i
) and the reflected power (P
r
) at
low level.
The nominal output impedance is 50 ohms, and each output should be connected to a
50
Ω
test system or terminated with 50
Ω
load supplied with the amplifier.
Nominal Output
Impedance (ohms)
Amplifier Power
Level (Watts)
Nominal Output
Level (dBc)
Flatness
(dB)
50
<700
40
+/- 3
50
> 700
50
+/- 3
The above parts can be supplied as spares or replacement items. The part number
must be quoted when ordering.
7.5
Line supply input connector
The CBA series power supply is equipped with a IEC or Neutrik Powercon inlet for
single phase models and a high current 3 phase / 5 wire MS connector for high power
models. The amplifier systems are supplied with mating power cords.
i
i
Note:
Mains inlet connectors are model dependent.
Rear Panel Single Phase
Neutrik ‘Powercon’
3 Phase 5 Wire MS Connector
Rear Panel Single Phase
IEC