CALIBRATION
Calibration is not normally required after the FPDC is shipped. However, if
necessary, calibration is easily performed through the Controller module interface
with SCPI commands, requiring only a meter and a mating connector.
5.6.1
S
COPE
The factory calibration consists of setting the 4 outputs to nominal, that is +5VDC
= 5.000, etc. The following procedures can be used to reestablish this as
required.
5.6.2
R
ECOMMENDED
C
ALIBRATION
E
QUIPMENT
DMM, with at least 6 ½ digit accuracy and must be within its calibration period.
Calibration Power Connector:
•
Mating connector: 21 pin D_SUB, special: Positronic Subminiature-D
CBC Series, CBC21WA4M1000Z (crimp signal contacts)
•
Four male contacts; high-current male contact ratings: MC4012D rated at
20A with 12AWG wire
•
22 AWG insulated wires
5.6.3
C
ALIBRATION
S
ETUP
Calibration can be done without load, therefore only a meter and a specially
configured mating connector is required, made up as follows:
(
Note:
these Test Connectors are used during performance verification as well).
FPDC
P
OWER
C
ONNECTOR FOR
C
ALIBRATION
In all cases, there is a wire for each of the 4 outputs and their corresponding
returns. These should be two to three inches in length and have the bare ends
soldered, (tinned) for convenient connection to the DMM. These are labeled as
Stub in the Type column.
Summary of Contents for Elgar ReFlex Power
Page 1: ...M380056 01 Rev L www programmablepower com ReFlex Power Operation Manual...
Page 2: ......
Page 3: ......
Page 4: ......
Page 6: ...ii This page intentionally left blank...
Page 8: ...iv This page intentionally left blank...
Page 10: ...vi This page intentionally left blank...
Page 21: ...M380056 01 Rev L xvii This page intentionally left blank...
Page 22: ......
Page 85: ...ReFlex Power Controller ReFlex Power 3 22 M380056 01 Rev L This page intentionally left blank...
Page 89: ...AC Power Supplies ReFlex Power 4 4 M380056 01 Rev L Figure 4 1 ACPS Module Front Panel 875VA...
Page 120: ...ReFlex Power AC Power Supplies M380056 01 Rev L 4 35 Figure 4 11 Parallel Output Configuration...
Page 147: ...AC Power Supplies ReFlex Power 4 62 M380056 01 Rev L RST n...
Page 157: ...AC Power Supplies ReFlex Power 4 72 M380056 01 Rev L 26 Reset the unit RST n...
Page 274: ...ReFlex Power DC Power Supplies M380056 01 Rev L 6 71 18 Turn off the output RST n...
Page 275: ...DC Power Supplies ReFlex Power 6 72 M380056 01 Rev L This page intentionally left blank...
Page 279: ...Active Loads ReFlex Power 7 4 M380056 01 Rev L Figure 7 1 LPAL 375W Front Panel...
Page 280: ...ReFlex Power Active Loads M380056 01 Rev L 7 5 Figure 7 2 HPAL 750W Front Panel...
Page 281: ...Active Loads ReFlex Power 7 6 M380056 01 Rev L Figure 7 3 Typical Active Load Rear Panel...
Page 359: ...Active Loads ReFlex Power 7 84 M380056 01 Rev L This page intentionally left blank...