ReFlex Power™
DC Power Supplies
M380056-01 Rev L
6-59
4. Configure the host controller for communications with the ReFlex
Power™ Controller module.
5. Turn on the AC/DC input service.
6. The modules will first execute a power-on self-test. Also the
internal fans are run at maximum speed for several seconds, and
then back to slow speed.
7. In the following paragraphs, commands include a channel
number,
[n]
. The channel number corresponds to the slot of the
ReFlex Power™ Mainframe where the module is located, counting
left to right, 1 through 12. For example:
SOUR[n]:VOLT 5 will be
SOUR1:VOLT 5 for slot-1
SOUR2:VOLT 5 for slot-2
8. Additionally, model specific parameter values must be added for
full-scale voltage and current. They are shown in the following
examples as floating point numerical values,
<fval>
. For the DC
power supply modules, the values are as follows:
Full-Scale Voltage:
RFP-D1016-021-XXXX: 16
RFP-D1065-5A1-XXXX: 65
RFP-D2033-030-XXXX: 33
RFP-D2450-2A3-XXXXA3: 450
Full-Scale Current:
RFP-D1016-021-XXXX: 20.6
RFP-D1065-5A1-XXXX: 5.1
RFP-D2033-030-XXXX: 30
RFP-D2450-2A3-XXXXA3: 2.3
Therefore, for an RFP-D1016-021-XXXX module in slot 1, the command
for full-scale voltage would be
SOUR1:VOLT 16
, while for an RFP DC
065-5A1 module it would be
SOUR1:VOLT 65
.
9. Verify communications with the ReFlex Power™ Controller
module by issuing an SCPI
*IDN[n]?
, where “n” is a channel
number that corresponds to the slot of the ReFlex Power™
Mainframe where the module is located, counting left to right, 1
through 12.
10. The ReFlex Power™ Controller module should respond with its
identification string.
11. Verify communications with the ReFlex Power™ DC power supply
module by issuing an SCPI
*IDN[n]?
,
where “n” is a channel
number that corresponds to the slot of the ReFlex Power™
Mainframe where the module is located, counting left to right, 1
through 12.
Summary of Contents for Elgar ReFlex Power
Page 1: ...M380056 01 Rev L www programmablepower com ReFlex Power Operation Manual...
Page 2: ......
Page 3: ......
Page 4: ......
Page 6: ...ii This page intentionally left blank...
Page 8: ...iv This page intentionally left blank...
Page 10: ...vi This page intentionally left blank...
Page 21: ...M380056 01 Rev L xvii This page intentionally left blank...
Page 22: ......
Page 85: ...ReFlex Power Controller ReFlex Power 3 22 M380056 01 Rev L This page intentionally left blank...
Page 89: ...AC Power Supplies ReFlex Power 4 4 M380056 01 Rev L Figure 4 1 ACPS Module Front Panel 875VA...
Page 120: ...ReFlex Power AC Power Supplies M380056 01 Rev L 4 35 Figure 4 11 Parallel Output Configuration...
Page 147: ...AC Power Supplies ReFlex Power 4 62 M380056 01 Rev L RST n...
Page 157: ...AC Power Supplies ReFlex Power 4 72 M380056 01 Rev L 26 Reset the unit RST n...
Page 274: ...ReFlex Power DC Power Supplies M380056 01 Rev L 6 71 18 Turn off the output RST n...
Page 275: ...DC Power Supplies ReFlex Power 6 72 M380056 01 Rev L This page intentionally left blank...
Page 279: ...Active Loads ReFlex Power 7 4 M380056 01 Rev L Figure 7 1 LPAL 375W Front Panel...
Page 280: ...ReFlex Power Active Loads M380056 01 Rev L 7 5 Figure 7 2 HPAL 750W Front Panel...
Page 281: ...Active Loads ReFlex Power 7 6 M380056 01 Rev L Figure 7 3 Typical Active Load Rear Panel...
Page 359: ...Active Loads ReFlex Power 7 84 M380056 01 Rev L This page intentionally left blank...