DC Power Supplies
ReFlex Power™
6-60
M380056-01 Rev L
12. The DC power supply module should respond with its
identification string. The default settings of the module will not be
affected.
S
TANDALONE
C
ONFIGURATION
O
PERATION
C
HECK
1. Connect the output for standalone operation per the section,
Standalone Configuration.
2. Connect appropriate instrumentation for measuring the output
voltage and current, as well as a load.
3. Perform the power-on verification test per the section, Power-On
Check.
4. Turn on the isolation and remote sense relays, turn on the output
converter, and program full-scale voltage and current with the
following commands:
*RST[n]
OUTP[n]:ISOL 1
OUTP[n]:SENS 1
OUTP[n]:STAT 1
SOUR[n]:VOLT <fval>
SOUR[n]:CURR <fval>
5. Measure the output voltage and current with the external
instruments.
6. Ensure that the actual values of the output parameters are within
specifications of the programmed values.
7. Query the values of the output parameters with the following
commands:
MEAS[n]:VOLT?
MEAS[n]:CURR?
8. Ensure that the readback values of the output parameters are
within specifications of the actual values.
9. Turn off the output with the following command:
*RST[n]
P
ARALLEL
C
ONFIGURATION
O
PERATION
C
HECK
1. Before attempting to verify parallel operation, perform the power-
on test of the individual modules per the section, Power-On
Check, and then the standalone operation test per section,
Standalone Configuration.
2. Connect the outputs for parallel operation per the section, Parallel
Configuration. Ensure that the outputs and remote sense are
Summary of Contents for Elgar ReFlex Power
Page 1: ...M380056 01 Rev L www programmablepower com ReFlex Power Operation Manual...
Page 2: ......
Page 3: ......
Page 4: ......
Page 6: ...ii This page intentionally left blank...
Page 8: ...iv This page intentionally left blank...
Page 10: ...vi This page intentionally left blank...
Page 21: ...M380056 01 Rev L xvii This page intentionally left blank...
Page 22: ......
Page 85: ...ReFlex Power Controller ReFlex Power 3 22 M380056 01 Rev L This page intentionally left blank...
Page 89: ...AC Power Supplies ReFlex Power 4 4 M380056 01 Rev L Figure 4 1 ACPS Module Front Panel 875VA...
Page 120: ...ReFlex Power AC Power Supplies M380056 01 Rev L 4 35 Figure 4 11 Parallel Output Configuration...
Page 147: ...AC Power Supplies ReFlex Power 4 62 M380056 01 Rev L RST n...
Page 157: ...AC Power Supplies ReFlex Power 4 72 M380056 01 Rev L 26 Reset the unit RST n...
Page 274: ...ReFlex Power DC Power Supplies M380056 01 Rev L 6 71 18 Turn off the output RST n...
Page 275: ...DC Power Supplies ReFlex Power 6 72 M380056 01 Rev L This page intentionally left blank...
Page 279: ...Active Loads ReFlex Power 7 4 M380056 01 Rev L Figure 7 1 LPAL 375W Front Panel...
Page 280: ...ReFlex Power Active Loads M380056 01 Rev L 7 5 Figure 7 2 HPAL 750W Front Panel...
Page 281: ...Active Loads ReFlex Power 7 6 M380056 01 Rev L Figure 7 3 Typical Active Load Rear Panel...
Page 359: ...Active Loads ReFlex Power 7 84 M380056 01 Rev L This page intentionally left blank...