ReFlex Power™
Active Loads
M380056-01 Rev L
7-19
the AC input leakage current could exceed 3.5mA, a second safety
ground connection is required. It should be connected to the safety
ground stud on the rear panel of the Mainframe.
WARNING
A separate, dedicated safety ground wire must be connected to the
Mainframe rear panel safety ground stud. Operating the ReFlex Power™
system with the safety ground wire disconnected could result in a shock
hazard.
M
ATING
C
ONNECTOR
K
IT
Load (HPAL/LPAL) Mating Connector Kit - AMETEK Part No. 5380273-01, mates
with RFP-L3500-375-XXXX and RFP-L3500-750-XXXX, and includes the
following for both the Interface and DC Input connectors:
Bill of Material
Item
AMETEK
Part No.
Description
Qty
Manufacturer
Part No.
Manufacturer
Suggested Source(s)
1
855-363-08
Conn, 4P, 8/16AWG, Plug,
SR, Skt
1
MS3106F-20-24S
Amphenol,
ITT Cannon
Arrow Electronics:
2
856-214-09
Conn, 9P, DSUB, 20-
24AWG, Crimp, Male
1
SD9M1000Z
Positronic Industries
Positronic Ind.
http://www.connectpositronic.com/default.cfm
3
856-247-10
Conn, Backshell, 9P,
DSUB, 2 PC
1
D9000Z00
Positronic Industries
Positronic Ind.
http://www.connectpositronic.com/default.cfm
R
ECOMMENDED
T
OOLS
(N
OT
I
NCLUDED WITH
M
ATING
C
ONNECTOR
K
IT
)
Hand crimp: Positronic Industries P/N 9507-0-0-0
Pneumatic crimp: Positronic Industries P/N 9550-1-0
Insertion/extraction: Positronic Industries P/N M81969/1-02
I
NTERFACE
C
ONNECTOR
The user Interface connector (see Figure 7-6 with wiring diagram) provides
terminations for external connections to digital and analog control signals (see
Table 7-2 for pinouts).
Connector: Positronic Industries P/N SD9M1000Z, AMETEK P/N 856-214-09
Crimp contacts: Positronic Industries P/N MC7520D (initially supplied with connector)
Backshell: Positronic Industries P/N D9000Z00, AMETEK P/N 856-247-10
Wire size: Maximum gauge 20 AWG (22 AWG recommended)
Maximum length 10 meters.
Summary of Contents for Elgar ReFlex Power
Page 1: ...M380056 01 Rev L www programmablepower com ReFlex Power Operation Manual...
Page 2: ......
Page 3: ......
Page 4: ......
Page 6: ...ii This page intentionally left blank...
Page 8: ...iv This page intentionally left blank...
Page 10: ...vi This page intentionally left blank...
Page 21: ...M380056 01 Rev L xvii This page intentionally left blank...
Page 22: ......
Page 85: ...ReFlex Power Controller ReFlex Power 3 22 M380056 01 Rev L This page intentionally left blank...
Page 89: ...AC Power Supplies ReFlex Power 4 4 M380056 01 Rev L Figure 4 1 ACPS Module Front Panel 875VA...
Page 120: ...ReFlex Power AC Power Supplies M380056 01 Rev L 4 35 Figure 4 11 Parallel Output Configuration...
Page 147: ...AC Power Supplies ReFlex Power 4 62 M380056 01 Rev L RST n...
Page 157: ...AC Power Supplies ReFlex Power 4 72 M380056 01 Rev L 26 Reset the unit RST n...
Page 274: ...ReFlex Power DC Power Supplies M380056 01 Rev L 6 71 18 Turn off the output RST n...
Page 275: ...DC Power Supplies ReFlex Power 6 72 M380056 01 Rev L This page intentionally left blank...
Page 279: ...Active Loads ReFlex Power 7 4 M380056 01 Rev L Figure 7 1 LPAL 375W Front Panel...
Page 280: ...ReFlex Power Active Loads M380056 01 Rev L 7 5 Figure 7 2 HPAL 750W Front Panel...
Page 281: ...Active Loads ReFlex Power 7 6 M380056 01 Rev L Figure 7 3 Typical Active Load Rear Panel...
Page 359: ...Active Loads ReFlex Power 7 84 M380056 01 Rev L This page intentionally left blank...