QUICK-START GUIDE 
AND SAFETY INSTRUCTIONS

 

 

NSG 4070C 

NSG 4070C-35 
NSG 4070C-40 
NSG 4070C-45 
NSG 4070C-60 
NSG 4070C-80 
NSG 4070C-110 
NSG 4070C-0

 

Summary of Contents for NSG 4070C

Page 1: ...QUICK START GUIDE AND SAFETY INSTRUCTIONS NSG 4070C NSG 4070C 35 NSG 4070C 40 NSG 4070C 45 NSG 4070C 60 NSG 4070C 80 NSG 4070C 110 NSG 4070C 0 ...

Page 2: ...nd Safety Guide 2 20 AMETEK CTS GmbH Sternenhofstrasse 15 4153 Reinach BL1 Switzerland Phone 41 61 204 41 11 Fax 41 61 204 41 00 URL www ametek cts com Copyright 2021 AMETEK CTS GmbH All right reserved Specifications subject to change ...

Page 3: ...the generator 7 1 12 Dangers concerning the EUT 7 1 13 Applicable safety standards 7 1 14 Intended use 7 1 15 Warranty Terms 8 1 16 Prohibition of unauthorized conversions and modifications 8 1 17 Specific accessories required for safety reason 8 1 18 Procedure in case of hazard 8 2 Unpacking storage and transport 9 2 1 General 9 2 2 Storage and transport 9 2 3 Unpacking 9 2 4 Scope of delivery 9 ...

Page 4: ...e Faraday cage level limitation and or spatial distance are common measures This symbol indicates access of persons with pacemakers prohibited This symbol indicates the ground terminal This symbol indicates the protective earth terminal CAUTION The CAUTION symbol indicates a potential hazard It calls attention to a procedure practice or condition which if not followed could possibly cause damage t...

Page 5: ...ction cable carefully Hold the plug when unplugging the cable Never use the product if the connection cable or plug is damaged Avoid touching conductive parts unless they have been de energized by suitable means and secured against being switched on again for the period of handling Industrial connectors often have insufficient pro tection against electric shock due to their application 1 5 Connect...

Page 6: ...ion holes also on the underside Ventilation should not be impeded by covering the ventilation openings with items or other equipment Avoid high temperatures Allow for sufficient heat dispersion when installed in a rack Do not place the prod uct on radiators or fan heaters The ambient temperature must not exceed the maximum specified tempera ture of this product Keep the test area clean and well li...

Page 7: ...aged through internal overloads caused by the control electronics being disrupted The EUT may even begin to burn As soon as the EUT shows signs of damage the test should be stopped and the equipment under test should be switched off Possible erroneous behavior by the EUT for example a robotic device may misbehave or a temperature regulator may fail Even when power is off capacitors may retain an e...

Page 8: ...sembled in any way without AMETEK CTS s consent or is used in combination with items articles or materials not authorized by AMETEK CTS The buyer may not assert any claim that the products are not in conformity with any warranty until the buyer has made all payments to AMETEK CTS provided for in the purchase order agreement 1 16 Prohibition of unauthorized conversions and modifications The user is...

Page 9: ...t from dampness heat cold and rain Do not throw Do not sit or stand on the instrument and packaging 2 3 Unpacking Is the packaging damaged If YES transportation company Are all the packages present and correct If NO transportation company Open the packaging remove the accessories Grip the instrument at the sides and lift it from the packaging Are the instrument or accessories damaged If YES transp...

Page 10: ...odulation Up to three pulse modulation settings can be defined in order to create an envelope NSG 4070C meets the requirements of ISO DTS 7637 4 Annex C Test generator for pulsed sinusodial disturbances pulse A The powerful and easy to use firmware makes the NSG 4070 independent from an external PC and control soft ware however it can also be remote controlled for system operation A state of the a...

Page 11: ...ondition menu cancelling of entries error messages to the preceding higher level menu Displays menus softkeys and results Power meter inputs impedance Z 50 Ω BNC socket Caution Maximum input level 20 dBm for channel 2 and 3 Maxi mum input level 27 dBm for channel 1 If necessary use voltage limiters or attenuators Amp out power amplifier output the power amplifier is optional RF out synthesizer out...

Page 12: ...NSG 4070 using USO 4013 7 Network connector 10 100 Ethernet USB device connector 9 USB host connector 10 Fans for cooling the internal parts of the unit 11 BNC sockets a Monitoring input analog BNC socket 0 24 V Ri 15 kΩ 6 mV resolution b Monitoring digital input BNC socket 0 24 V via optical coupler Ri 1 5 kΩ switching threshold approx 2 to 3 V c External modulation input BNC socket Impedance 10 ...

Page 13: ...AMETEK CTS NSG 4070 Quick Start and Safety Guide 13 20 4 Quick Start ...

Page 14: ...AMETEK CTS NSG 4070 Quick Start and Safety Guide 14 20 ...

Page 15: ...AMETEK CTS NSG 4070 Quick Start and Safety Guide 15 20 ...

Page 16: ... PC Press Setup Press Remote Press RS232 optical Press Back Press Baudrate setup Change the settings as required Default value is 11500 Baud Connect the NSG 4070 USO 4013 and PC as shown in the figure The device manager under Windows 10 shows the USO 4013 after successful driver installa tion The port number in the example COM 4 must be entered in the application software ...

Page 17: ...TS NSG 4070 Quick Start and Safety Guide 17 20 6 Applications 6 1 IEC 61000 4 6 System calibration with CDN Testing with CDN System calibration with EM clamp or CIP Testing with EM clamp or CIP Saturation check ...

Page 18: ...070 Quick Start and Safety Guide 18 20 6 2 BCI according ISO 11452 4 System calibration Substitution testing Closed Loop testing 6 3 BCI according MIL STD 461G CS114 example Level 2 5 5 System calibration Verification ...

Page 19: ...AMETEK CTS NSG 4070 Quick Start and Safety Guide 19 20 Testing 6 4 ISO DTS 7637 4 Pulse A System calibration Testing 6 5 ISO 11452 5 System calibration Closed Loop testing ...

Page 20: ...ited due to the durability of the contacts AMETEK CTS can replace the worn connectors No modifications may be made to the NSG 4070 and accessories by the user 7 2 Cleaning The cleaning shall be done with dry cloth If a wed cleaning would become necessary make sure that no humidity will enter inside of the unit and clean the instrument housing with a damp cloth using a little mild non abrasive hous...