SXRXLXX1 - SIL IntelliPoint RF Series User's Manual
34
5.1 Approvals
The IntelliPoint RF Point Level System Transmitter has been evaluated
as Explosion-proof for use in Class I, Division 1, Groups A, B, C, and
D, Dust-Ignition proof for use in Class II and III, Division 1, Groups E,
F, and G; Non-incendive for use in Class I, Division 2, Groups A, B, C,
and D; Suitable for use in Class II and III, Division 2, Groups F and G
Hazardous (Classified) Indoor and Outdoor (Type 4, 4X, IP66) Locations
with Intrinsically Safe connections to Class I, II, and III, Division 1, Groups
A, B, C, D, E, F, and G Hazardous (Classified) locations in accordance
with control drawing 420-0004-144-CD for the RxLx and SxRxL Series
and Control Drawing 420-0004-173-CD for the RxTx and SxRxT Series;
Intrinsically Safe for use in Class I, II, and III, Division 1, Groups A, B, C,
D, E, F, and G hazardous (Classified) locations in accordance with entity
requirements and control drawing 420-0004-173-CD.
Integral
Remote
Temperature Class Process Temperature
T5
100°C
T4
135°C
T3
200°C
T2
230°C
2460
ATEX (FM14ATEX0049)
II 1 G Ex ia IIC T5... T2 -30°C ≤ TAMB ≤ +70°C; IP66
II 1 D Ex ia IIIC T90°C -30°C ≤ TAMB ≤ +70°C; IP66
II 1 G Ex ia IIC T5... T2 -30°C ≤ TAMB ≤ +70°C; IP66
II 1 D Ex ia IIIC T90°C -30°C ≤ TAMB ≤ +70°C; IP66
IECEX (FTZU 18.0007X)
Ex db ia [ia Ga] IIC T5 Gb/Ga
Ex tb ia [ia Da] IIIC T90ºC Db/Da
-30ºC ≤ Ta ≤ 58ºC
Reference control drawing 420-0004-563-CD for entity and installation requirements
System
Sensor
Ex ia IIC T5 Ga
Ex ia IIIC T90ºC Da
-30ºC ≤ Ta ≤ 58ºC
Special Condition for Safe Use
1. THE EQUIPMENT SHALL NOT BE APPLIED IN AN EXPLOSIVE DUST ATMOSPHERE WHERE HIGH
ELECTROSTATIC CHARGING PROCESSES ARE PRESENT THAT COULD RESULT IN PROPAGATING BRUSH
DISCHARGES.
2. CONSULT THE MANUFACTURER IF DIMENSIONAL INFORMATION ON THE FLAMEPROOF JOINTS IS
NECESSARY.
3. AMBIENT TEMPERATURE RANGE:
-30°C TO +58°C FOR RXLX/SXRXTX INTELLIPOINT RF LEVEL SYSTEM
-30°C TO +70°C FOR RXTX/SXRXTX INTELLIPOINT RF TWO-WIRE POINT LEVEL SYSTEM
Summary of Contents for SIL IntelliPoint RF S*R*L Series
Page 4: ...Contents...
Page 6: ...Section 1...
Page 38: ...SXRXLXX1 SIL IntelliPoint RF Series User s Manual 32 Section 5...
Page 41: ...Specifications 35 Section 6...
Page 43: ...Control Drawings 37 6 1 FM FMc Control Drawings Continued...
Page 44: ...SXRXLXX1 SIL IntelliPoint RF Series User s Manual 38 6 1 FM FMc Control Drawings Continued...
Page 45: ...Control Drawings 39 6 1 FM FMc Control Drawings Continued...
Page 46: ...SXRXLXX1 SIL IntelliPoint RF Series User s Manual 40 6 1 FM FMc Control Drawings Continued...
Page 47: ...Control Drawings 41 6 1 FM FMc Control Drawings Continued...
Page 48: ...SXRXLXX1 SIL IntelliPoint RF Series User s Manual 42 6 1 FM FMc Control Drawings Continued...
Page 56: ...SXRXLXX1 SIL IntelliPoint RF Series User s Manual 50 6 2 ATEX Control Drawings...
Page 57: ...Control Drawings 51 6 2 ATEX Control Drawings Continued...
Page 66: ...SXRXLXX1 SIL IntelliPoint RF Series User s Manual 60 6 4 IECEx Control Drawings...
Page 67: ...Control Drawings 61 6 4 IECEx Control Drawings Continued...
Page 75: ...Control Drawings 69 6 5 Mounting and Wiring for Spark Protector Drawings...
Page 77: ...Control Drawings 71 6 5 Mounting and Wiring for Spark Protector Continued...
Page 78: ...SXRXLXX1 SIL IntelliPoint RF Series User s Manual 72 6 6 Adding a Padded Capacitor...
Page 79: ...Control Drawings 73 6 6 Adding a Padded Capacitor Continued...
Page 80: ...SXRXLXX1 SIL IntelliPoint RF Series User s Manual 74 6 6 Adding a Padded Capacitor Continued...
Page 81: ...Control Drawings 75 6 7 Dual Seal Assembly for 700 Series Sensing Elements...
Page 82: ...SXRXLXX1 SIL IntelliPoint RF Series User s Manual 76 6 7 Dual Seal Assembly Continued...
Page 83: ...Control Drawings 77 6 7 Dual Seal Assembly Continued...
Page 84: ...Appendix A...
Page 88: ...SXRXLXX1 SIL IntelliPoint RF Series User s Manual A 4 Appendix B...
Page 90: ...SXRXLXX1 SIL IntelliPoint RF Series User s Manual B2 EXIDA Report Results...