Asterion DC Multioutput ASA Series Operational Manual
M330516-01
4-13
Figure 4-17: Regulation mode status channel 2
Figure 4-18: Regulation mode status channel 3
4.7
Output ON/OFF Status
Remote External user interface (26 pin connector) provided with Output ON/OFF
Status for each channel of the power supply; refer Table 4-1 for pin out details. an
output signal with High state (3 to 30V) indicates that the Output of power supply is
enabled, and Low state indicates that the output of power supply is disabled. Output
status signal can be monitored on CH-OUTPUT- ON/OFF-STATUS pins; refer Figure
4-19, Figure 4-20 and Figure 4-21 for the respective pin out numbers.
Figure 4-19: Output ON/OFF Status channel 1