Asterion DC Multioutput ASA Series Operational Manual
M330516-01
3-50
Figure 3-39: Configuration Menu screen 2
The following menus are available in the Configuration Screen top-level menu:
•
Measurement Settings
•
Remote Inhibit Settings
•
User V/I Limits
•
Current Ref. Mode
•
Voltage Ref. Mode
•
Output On/Off Delay
•
PONS
3.4.6.1
M
EASUREMENTS
S
ETTING
The Measurement Settings screen sets the number of readings for each channel to
average together to reduce noise in the readback. Refer to Figure 3-40.
Up-Arrow and Home button will return to HOME MENU screen 2; Refer Figure 3-14.
Figure 3-40: Measurement Settings Screen
The Measurement Settings screen has the following fields:
Entry
Description
Volt Avg Samples
Sets the number of voltage readings to the voltage readback. Allows
to set a value between 1 to 5.
The Default value is PONS Measurements settings.
Curr Avg Samples
Sets the number of current readings to average the current readback.
Allows to set a value between 1 to 9.
The Default value is PONS Measurements settings.