Table 6-2
Inspection and Corrective Action
ITEM
INSPECT FOR
CORRECTIVE ACTION
Connector plugs and
jacks
Chassis, fan and
extruded
heatsinks
External
Electrical
Wiring
External
Solder
Connections
Dirt and moisture
buildup
Front
panel
controls
and
meters
Loose, bent or corroded
contacts, damage or improper
seating in mating connector
Dirt and Corrosion
Broken, burned or pinched
wire; frayed, worn or missing
insulation
Corrosion, loose, cracked, or
dirty connections
Short circuits, arcing, corrosion,
overheating
Dirt and corrosion
Clean contacts with solvent
moistened cloth, soft bristle brush,
small vacuum, or low compressed
air.
Replace damaged or corroded
connectors.
Clean with cloth moistened with
soapy water.
Repair or replace defective wires.
Clean and resolder connections.
Clean as required.
Clean with cloth moistened with
soapy water.
Use a Kimwipe tissue and GTC
glass cleaning compound to clean
the meter faces.
M550004-01