Installation
Sorensen SGA Series
2-10
M550129-01 Rev AF
Power Supply Type
Connection
Connection Description
4 kW to 15 kW, 3U
AC Input
Feed-Through terminal block with
compression terminals
20 kW to 30 kW, 6U
AC Input
Bus Bar with holes for 1/4
–20 bolts
All 3U and 6U
Chassis Safety Ground
1/4-20 stud
Table 2
–4. Input Terminal Connections
CAUTION!
To prevent damage to the AC input connector of the 3U units, follow torque
specifications, and, if a wire ferrule is used, ensure that it is properly sized
and that it has been crimped with the appropriate ferrule crimping tool.
AC Input Connector for 3U Models
Recommended torque for the AC input connector screws: 17.7 in-lb to
20.4 in-lb (2 Nm to 2.3 Nm).
Wire ferrules are recommended, properly sized to match the wire gauge; use
appropriate crimp tool for the ferrule size.
Wire insulation should be stripped to
5/8”, maximum.
For more information on the AC input connector, refer to the manufacturer
(Phoenix Contact) part number HDFKV 16 at their website,
www.phoenixcontact.com.
Power Supply Type
Connection Description
4 kW to 15 kW, 10V-30V models
Bus bars with two holes
for 1/2” bolts on each terminal
(POS. and NEG.)
5 kW to 15 kW, 40V-1000V models
40V-600V models: bus bars with single holes for 3/8" bolts
on each terminal (POS. and NEG.)
800V and 1000V models: 1/4-20 studs for each terminal
(POS. and NEG.)
20 kW to 30 kW
Bus bars with single holes for 3/8" bolts for each terminal
(POS. and NEG.)
Table 2
–5. Output Terminal Connections
Manufacturer
Low Current
High Current
Panduit
P, PV, or PN series, or
equivalent
Standard stranded wire: LCA Series, or equivalent
Flexible stranded wire: LCAX Series, or equivalent
Note:
Contact lug manufacturer for recommended crimping tool.
Table 2
–6. Recommended Lugs
Tool
Manufacturer
Manufacturer P/N
Crimping
Molex
11-01-0197
Extracting
Molex
11-03-0044
Table 2
–7. Recommended Sense Connector Tools
Summary of Contents for Sorensen SGA Series DC
Page 1: ...M550129 01 Rev AF www programmablepower com SGA Series DC Power Supplies Operation Manual ...
Page 2: ......
Page 50: ...Installation Sorensen SGA Series 2 30 M550129 01 Rev AF This page intentionally left blank ...
Page 82: ...Operation Sorensen SGA Series 3 32 M550129 01 Rev AF This page intentionally left blank ...
Page 90: ...Installation Sorensen SGA Series 4 8 M550129 01 Rev AF This page intentionally left blank ...
Page 94: ...Maintenance Sorensen SGA Series 5 4 M550129 01 Rev AF This page intentionally left blank ...
Page 97: ...M550129 01 Rev AF Index 3 This page intentionally left blank ...