Remote
Operation
5-40
M370430-01 Rev F
Table 5-12
OPERation Status Register
Bit
Bit Weight
Bit Name
Description
0
1
CALibrating
Indicates that the supply is in CALibration Mode.
1
2
SETTling
Not implemented
2
4
RANGing
Not implemented
3
8
SWEeping
Not implemented
4
16
MEASuring
Not implemented
5
32
Waiting for Arm
Not implemented
6
64
Waiting for Trigger
Not implemented
7
128
CORRecting
Not implemented
8
256
Not Used
Not Used
9
512
SHUTdown Summary
Reflects the summary of the SHUTdown
Sub-Register.
10
1024
Local Lockout
Front panel lockout
11
2048
Current Share Summary
Reflects the summary of the CSHare Sub-Register.
12
4096
Constant Voltage Mode
Reflects the output mode of the supply.
13
8192
Constant Current Mode
Reflects the output mode of the supply.
14
16384
Program Running
Indicates if an Autosequence program is currently
running.
The operation shutdown status register describes the cause of the power
supply shutting down the output. More than one bit may be active and
multiple actions will be required to restart the unit. The protection
shutdown sub-register indicates which protection mechanisms have
caused the power supply to shutdown.
Summary of Contents for Sorensen XG 100-15
Page 2: ......
Page 93: ...Local Operation M370430 01 Rev F 3 47 3 Figure 3 5 Series Operation ...
Page 99: ...Local Operation M370430 01 Rev F 3 53 3 ...
Page 100: ...Local Operation 3 54 M370430 01 Rev F ...
Page 220: ...Communications Options 6 14 M370430 01 Rev F ...
Page 244: ...Communications Options 6 38 M370430 01 Rev F ...
Page 252: ...Communications Options 6 46 M370430 01 Rev F ...
Page 292: ......
Page 329: ...M370430 01 Rev F A 37 A APPENDIX A SCPI Command Reference ...
Page 330: ......
Page 368: ...APPENDIX D Rack Mount Options and Installation Instructions D 12 M370430 01 Rev F ...
Page 369: ...APPENDIX D Rack Mount Options and Installation Instructions M370430 01 Rev F D 13 ...
Page 370: ......
Page 395: ...Rack Mount Options and Installation Instructions M370430 01 Rev F E 25 ...
Page 396: ......
Page 399: ......