Calibration
and Troubleshooting
7-6
M370430-01 Rev F
Calibrating the Output Voltage
Gain calibration of the power supply has the greatest effect on the
accuracy in the high voltage range. Offset calibration has the greatest
affect on accuracy of the power supply at low voltages. The same
calibration command is used for the gain and offset calibrations. The
type of calibration is determined internally by the instrument depending
on if the set point is above 10% of the maximum output voltage value or
not. If it is above 10% of the maximum voltage, the calibration is a gain
calibration; if is below 10%, it is an offset calibration.
Gain Calibration
To perform gain calibration:
1.
Disconnect the power supply from the load.
2.
Connect the output terminals to a precision voltmeter.
3.
Turn both the power supply and the voltmeter to On.
4.
Set the current set point to maximum. Set the supply output to
90% of the nominal voltage level.
5.
Turn on the output power.
6.
Read the voltage value on voltmeter display.
7.
Type the SCPI command with voltage value as parameter
“data”.
For example, type :CAL:OUTP 138.3 if you had an XG 150-5.6
calibrating with the voltage set point set to 135 V and the voltmeter
was reading 138.3 volts.
Offset Calibration
To perform offset calibration:
1.
After performing gain calibration, set the programmed
voltage 10% from nominal.
2.
Read the voltage value on the voltmeter display.
3.
Type the SCPI command with voltage value as parameter
“data”.
For example, you would type : CAL: OUT P1 2 . 3 if you had an
XG 150-5.6 calibration with the voltage set point set to 10V and the
voltmeter was reading 12.3 volts.
Summary of Contents for Sorensen XG 100-15
Page 2: ......
Page 93: ...Local Operation M370430 01 Rev F 3 47 3 Figure 3 5 Series Operation ...
Page 99: ...Local Operation M370430 01 Rev F 3 53 3 ...
Page 100: ...Local Operation 3 54 M370430 01 Rev F ...
Page 220: ...Communications Options 6 14 M370430 01 Rev F ...
Page 244: ...Communications Options 6 38 M370430 01 Rev F ...
Page 252: ...Communications Options 6 46 M370430 01 Rev F ...
Page 292: ......
Page 329: ...M370430 01 Rev F A 37 A APPENDIX A SCPI Command Reference ...
Page 330: ......
Page 368: ...APPENDIX D Rack Mount Options and Installation Instructions D 12 M370430 01 Rev F ...
Page 369: ...APPENDIX D Rack Mount Options and Installation Instructions M370430 01 Rev F D 13 ...
Page 370: ......
Page 395: ...Rack Mount Options and Installation Instructions M370430 01 Rev F E 25 ...
Page 396: ......
Page 399: ......